Certificates
WYJ009-2002 2 1/4Cr-1Mo
1. Applicable scope
the technical conditions used in petrochemical industry hydrogenation reforming reaction is 2 1/4 Cr-1 Mo steel production.
2. Of the steel plate size and shape, weight and deviation should be allowed to meet the provisions of GB6654-1996 standard.
3. Technical requirements
3.1 chemical composition
The chemical composition of the steel plate should be in accordance with table 1:
Chart 1 Wt%
composition
|
C
|
Si
|
Mn
|
P
|
S
|
Cr
|
Mo
|
Ni
|
Cu
|
heat analysis
|
≤0.15
|
≤0.10
|
0.30~0.60
|
≤0.010
|
≤0.010
|
2.00~2.50
|
0.90~1.10
|
≤0.20
|
≤0.20
|
product analysis
|
≤0.15
|
≤0.15
|
0.25~0.66
|
0.012
|
0.012
|
1.95~2.62
|
0.85~1.15
|
≤0.20
|
≤0.20
|
composition
|
Sb*
|
Sn*
|
As*
|
(H)**
|
heat analysis
|
≤0.003
|
≤0.015
|
≤0.016
|
≤2PPm
|
product analysis
|
≤0.003
|
≤0.015
|
≤0.016
|
≤2PPm
|
Note: (1) * analysis results only for record, does not make the acceptance conditions.
(2) smelting furnace, finished product analysis according to analysis by rolling out a sampling inspection.
(3) the tempering embrittlement of full should satisfy the following requirements sensitivity:
X = (10 P + 5 Sb + 4 Sn + As) X 10-2 than 15 PPm
Type of element are in PPm content generation into, such as 0.01% to 100 PPm generation into.
J = (Si + Mn) (P + Sn) by 104 or 120
Type of element are to the percentage in the generation, such as 0.15% to 0.15 generation into.
1.1 delivery status: the steel plate to normalized (allows cooling) + tempering state delivery, is fire temperature should not be more than 968 ℃, 677 ℃temperature tempering shall not be less than.
1.2 mechanical properties:
The mechanical properties of the steel plate should comply with the provisions of the table 2 (sample for simulation of heat treatment after welding state) :
Chart 2
tensile strength
σb
MPa
|
yield
σ0.2
MPa
|
elongation
δ5
%
|
reduction of areaψ
%
|
cold impact test
b=2a
|
-30℃charpy impact test energy
J注(1)
|
540℃Gawra
σ0.2
MPa
|
515~690
|
≥310
|
≥18
|
≥45
|
bend
180°no cracking note (2)
|
≥54(AVG
)
≥48(single value)
|
≥205
|
Note: (1) the impact test, shall be recorded lateral expansion value and fibrous fracture percentage for reference.
(2) thick plate T≤25mm,d=2a;25mm<T≤50mm,d=2.5a