Product List
Gangsteel Material Solution
Email: admin@gangsteel.com
Sales: jack@gangsteel.com
1. applicable scope:
The technology conditions only apply to ≤100 mm thickness of the hydrogen and ≤50 mm thickness of the hydrogen 15 CrMoR steel production and inspection.
2. The reference standard (slightly)
3. The size, shape, weight and deviation should be allowed to meet the provisions of GB6654-1996 standard.
4. Mechanical properties
Steel grade |
Thick mm |
Reor Rp0.2 MPa |
Rm MPa |
A % |
Transverse impact energyJ |
Cold bend 180° b=2a |
Hydrogen15 CrMoR
|
≤50 |
≥295 |
450~590 |
≥19 |
temperature:0℃ Average value≥54 Signal value≥47 |
d=3a |
Hydrogen14 CrMoR
|
≤100 |
≥310 |
515~690 |
≥19 |
temperature:-10℃ Average value≥54 Signal value ≥47 |
d=3a |
The steel plate impact performance: impact do not conform to the provisions of the above, can retest . With a same steel plate should be taken another 3 samples again on sample inspection, before and after six samples shall meet the average rating, allowing two sample less than 54 J, but less than 47 J samples were allowed only one.
4.1 Steel plate after simulation of heat treatment after welding after high temperature tensile test shouldindicated in the contract.
4.2Steel plate grain degrees:≥6 grade
4.3Steel plate inclusions:A+C≤3.0,B +D≤3.0且A+B +C+D≤5.5
4.4Hardness of the steel plate:Steel plate delivery statushardness≤240HB
EN10028-2 P355GH for High-Strength Low-Alloy Columbium-Vanadium Structural Steel EN10025-2 S355J2 Structural St
We export A240 304L Stainless Coil 2B, NO.1 No.4 surface, the thickness 0.1mm to 3mm, 3mm to 22mm, Mother mill
ASTM A516 GR 70 equivalent materials is such as ASME SA516 GR 70, EN 10028 P355GH, and BS1501 224-490 A & B, sh