ASTM B898 is the specification for plate in which titanium, zirconium, tantalum, niobium or one of their alloys is bonded integrally and continuously to a base metal on one or both sides, generally for pressure vessels. Gangsteel uses it as the product standard for titanium-faced steel plate, with the cladding and backing each ordered to their own specifications.

ASTM B898 Titanium and Reactive Metal Clad Steel Plate - generated product illustration

Scope and Edition Basis

The current listing is B898-20, reapproved in 2026 as B898-20(2026). The clause references on this page were read from the published B898-20 text. B898 does not define a fixed list of composite grades: clause 6.1 lets the plate combine any agreed cladding and base metal, provided each conforms to its own specification.

What B898 governs and what it delegates
Topic B898-20 position Practical consequence
Cladding metal Chemistry per B265 (titanium), B551/B551M (zirconium), B708 (tantalum) or B393 (niobium) A titanium face is ordered as a B265 grade, for example Grade 1 or Grade 2
Base metal Steel or another metal plate conforming to its own plate specification A516 Grade 70 or Grade 60 is a common pressure-vessel choice; forgings are used for some tube sheets
Bonding method Any process giving a conforming product; explosion bonding, roll bonding and weld overlay are named For titanium on steel, explosion bonding is the usual commercial route
Cladding make-up Cladding may be edge butt-welded from several sheets before bonding and may consist of several layers Ask whether the face contains pre-bond seams
Heat treatment As needed in the cladding operation so both metals meet their specifications and the bond resists disbonding No universal furnace cycle; any post-weld cycle must be agreed

Mechanical and Bond Requirements

B898 keeps base-metal strength and bond strength apart. Tensile properties are taken on the base metal only, with the cladding removed from any specimen cut from the clad plate. The cladding need not meet the mechanical properties of its own specification unless the purchaser and manufacturer agree otherwise.

B898-20 test requirements
Requirement Value or rule Clause
Base-metal tension test Per base-metal specification; cladding removed before testing 7.5
Bond shear test Every clad plate; minimum 20 000 psi (137.9 MPa) 7.6.1
Shear specimen location From an end of the plate; for explosion cladding, at a location typical of the maximum distance from the initiation point 7.6.2
Shear retest Only for a defective specimen or method; two adjacent specimens, both must pass, one retest set only 7.6.3
Test condition Material as shipped, unless simulated post-cladding heat treatment (Supplementary Requirement S5) is specified 7.4
Bond integrity Pulse-echo straight-beam ultrasonic inspection after all mechanical and thermal processing 11.1

The 2020 revision made shear testing of every plate mandatory and tightened the ultrasonic procedure. A published summary of that revision by a clad manufacturer states that Quality Level B, 98% minimum sound bond, became the default ultrasonic level. Name the required level on the order rather than relying on the default.

Process, Delivery and Heat Treatment

Titanium and iron form brittle intermetallic compounds when melted together, so titanium cannot be fusion-welded to steel. Explosion bonding joins the two in the solid state, which is why it dominates titanium clad production. The same reaction at high temperature limits post-weld heat treatment of titanium-clad equipment in both temperature and time.

Manufacturing and delivery parameters for the enquiry
Parameter Order definition Engineering note
Bonding route Explosion bonding (usual for titanium on steel); roll bonding or weld overlay only if agreed and conforming B898 permits several methods but the plate must still meet the bond and ultrasonic requirements
Layer thickness Backing gage plus minimum facing gage in mm; single- or double-sided Allow facing margin for grinding, forming and weld restoration; total gage alone does not define the plate.
Final thermal condition As-clad condition, plus any simulated PWHT agreed under S5 Fix the PWHT temperature and time with the manufacturer before ordering so coupons can be tested after the simulated cycle
Surface and edges Clean titanium face, protected from iron contamination; edges cut as specified Thermal or mechanical cutting is allowed if it does not harm the product
Lead time Confirmed against the enquiry Depends on plate area, layer gages, quantity, thermal condition and witnessed inspection.

Inspection and Documentation

Request the base-metal and cladding certificates, the shear result for each plate (including any failed test and retest), the ultrasonic report with its quality level, and dimensional and flatness records. B898 Table 4 sets standard flatness of the cladding face; special flatness of 0.100 in. (2.5 mm) over any 36 in. (915 mm) span can be ordered for plates used flat.

Frequently Asked Questions

Which titanium grade is normally specified on a B898 clad plate?

Commercially pure Grade 1 or Grade 2 to B265 covers most orders. Grade 1 is the most formable; Grade 2 has higher strength. Palladium-bearing grades such as Grade 7 or Grade 11 are chosen when the process needs better resistance to reducing acids or crevice corrosion.

Is the 137.9 MPa shear value the strength of the plate?

No. It is the minimum interface shear strength of the bond. Plate strength comes from the base metal, which is tension-tested with the cladding removed.

Does every B898 plate get a shear test?

Yes. Since B898-20, a bond shear test is required on each clad plate, and all results, including failures and retests, are reported on the test report.

Can zirconium or tantalum clad plate be ordered to B898?

Yes. The specification also covers zirconium, tantalum, niobium and their alloys, with B551, B708 and B393 as the cladding specifications. These are lower-volume, project-specific products.

Why can a titanium-clad seam not be welded straight through like stainless clad?

Melting titanium into steel forms brittle intermetallics. Seams are made by welding the steel side, adding a titanium filler strip and welding a titanium batten strip over the joint to the titanium only.

Can titanium-clad plate be stress relieved after vessel welding?

Yes, but the temperature and time are limited to protect the bond. Agree the cycle in advance and order simulated heat-treatment coupons under Supplementary Requirement S5.

What does B898 say about flatness for tube sheets?

Standard flatness follows Table 4. Special flatness, machined flatness and plate supplied suitable for machining flat are separate ordering options.

What should a titanium clad enquiry include?

Base specification and grade, B265 titanium grade, backing and minimum cladding thickness, plate size or disc diameter, quantity, ultrasonic quality level, any simulated PWHT and the inspection requirements. Lead time is confirmed against the enquiry.

Related Products

A516 Grade 70 + titanium clad steel plate; ASTM A265 nickel-alloy clad plate; all clad steel plate combinations.

Other Products