Q355B tapered I-sections combine the hot-rolled Q355B material route in GB/T 1591 with the I-series geometry of GB/T 706. Their higher yield class can be useful where member strength governs, but replacing a lower-grade beam does not by itself improve its elastic deflection, torsional stiffness or restraint arrangement. Q355B here is not Q355N or Q355M, and a historical Q345B description is not a new Q355B certificate.
A model number identifies a family of tapered rolled profiles rather than a universal export size. For example, I20a has a 200 mm depth and a 100 mm flange width; its web and middle flange thickness are different dimensions. The material-test location, the flange seating surface and the beam stability calculation therefore require separate checks.
| Order field | Scope |
|---|---|
| Product | Q355B taper-flange I-beams |
| Material standard | GB/T 1591-2018 hot-rolled route |
| Section/product standard | GB/T 706: shape series, dimensions, tolerances and rolled-product requirements; numerical basis here 2016 |
| Delivery condition | Hot rolled; no normalized or TMCP route implied |
| Certification | Identify grade, heat/batch traceability, dimensional edition and agreed test reporting |
The numerical size tables on this page use GB/T 706-2016. On 22 November 2026 this is the effective edition. GB/T 706-2026 has been issued but does not take effect until 1 December 2026. These are not 2026-edition dimension tables. Specify the contractual dimensional edition, including its tolerances and mass basis, rather than silently applying a later edition to an earlier catalogue.
Selection and connection engineering
Use web sampling without overextending the result
GB/T 706-2016 Table 5 places ordinary tensile, bending and impact sampling for I-sections in the web, with specimen preparation under GB/T 2975. I45a illustrates why this matters: its middle flange is 18 mm, but its web is 11.5 mm. The ordinary web-based reference therefore remains the first yield band. That acceptance basis does not prove that every local thickness in the flange has a 355 MPa design strength.
Separate higher strength from stiffness and stability
Keeping the same cross-section while changing material grade does not materially change the elastic modulus of structural steel. If a lighter replacement is proposed, recalculate strong- and weak-axis deflection, lateral-torsional buckling, web shear and support bearing. The restraint assumed by the calculation must exist on the installed compression flange; the grade mark cannot provide it.
Bring the weld procedure into the grade discussion
Use actual heat chemistry and the applicable CEV limit together with joint thickness, restraint, consumable hydrogen and heat input. Do not select preheat from the Q355B name alone. A web-to-end-plate joint and a restrained flange weld can require different procedure decisions even on one beam. The flange taper also affects fit-up and available contact area.
Requalify a Q345B substitution instead of renaming it
Older drawings may call for Q345B. Compare the original material edition, yield bands, chemistry, toughness and acceptance documents against the proposed Q355B order. A dimensional match does not resolve that materials change. Likewise, do not substitute a GB/T 11263 H-section or an IPE at the same depth without recalculating the section and connection.
Mechanical properties: identify the tested thickness
| Nominal material thickness | Minimum ReH, MPa | Rm, MPa | Minimum A, % |
|---|---|---|---|
| d ≤16 mm | 355 | 470–630 | 22 |
| 16 < d ≤40 mm | 345 | 470–630 | 22 |
For these tables d denotes the applicable material-thickness reference: ordinarily the web in I-sections/channels and the leg in angles. It is not the overall height or leg width. Elongation values are the section/bar longitudinal reference; plate-specific specimen orientation or deductions must not be imported unchanged. Final specimen position, direction and preparation follow the ordered standards and contract, including GB/T 2975. These two bands cover the supplied reference series; they do not authorize other heavy-section products.
Ordinary GB/T 706-2016 Table 5 sampling is from the web. The largest listed web is 17 mm; only models 55c, 56c and 63c exceed 16 mm and enter the second yield band. For example, I45a has an 18 mm middle flange but an 11.5 mm web. Do not use the flange automatically as the ordinary test-band selector, or treat a web acceptance result as a uniform local flange design strength.
| Temperature | Longitudinal KV2 | Transverse option | Thickness qualification |
|---|---|---|---|
| +20 °C | 34 J | 27 J by agreement | Ordinary nominal-thickness trigger ≥6 mm; specimen size and energy acceptance follow the standard. |
Models 10, 12, 12.6 and 14 have webs thinner than 6 mm. Do not promise a full-size 10 × 10 mm impact specimen from a thinner section. Agree the applicable reduced-size specimen and energy rules where needed; below-trigger material is not automatically evidence of measured toughness. The 34 J figure is the longitudinal full-size reference, not a universal value for every specimen orientation or size. This +20 °C B quality does not establish cold-service suitability.
Heat chemistry and finished-product analysis
| Element | Limit | Acceptance note |
|---|---|---|
| C | 0.24 | For nominal material thickness >30 mm, maximum 0.22; this page does not apply the special >100 mm agreement route. |
| Si | 0.55 | Any restricted-silicon order needs its own agreed chemistry and applicable footnotes. |
| Mn | 1.60 | Heat-analysis maximum. |
| P | 0.035 | Sections/bars may use the standard’s +0.005 allowance, giving 0.040. |
| S | 0.035 | Sections/bars may use the standard’s +0.005 allowance, giving 0.040. |
| Cr | 0.30 | Heat-analysis maximum. |
| Ni | 0.30 | Heat-analysis maximum. |
| Cu | 0.40 | Heat-analysis maximum. |
| N | 0.012 | Analysis may be omitted with supplier guarantee. The limit is not restrictive with acid-soluble Al ≥0.015%, total Al ≥0.020%, or other nitrogen-binding additions; report the applicable basis. |
| Nb / V / Ti | Not mandatory | Q355 does not require a fixed microalloy addition in this table. Agreed alloy additions must be identified on the certificate. |
These values are for the hot-rolled Q355B route, not the separate normalized or thermomechanically rolled tables. A dash or absent mandatory addition is not a zero-content guarantee. The section/bar P and S allowance must not be concealed by quoting 0.035 as an unconditional rejection limit.
Keep heat analysis and product analysis distinct. Heat/ladle results identify the melt; a test on the finished rolled section is product analysis and is assessed using the applicable GB/T 222 permitted-deviation provisions. No numerical product-analysis deviations are supplied by the compiled dataset, so no extra tolerance has been invented here. If product analysis is required, agree the sampling, test method, material edition and deviation table before ordering; do not add a discretionary percentage to every heat limit.
Carbon equivalent: use the correct thickness and delivery route
| Nominal material thickness | Maximum CEV, % |
|---|---|
| ≤30 mm | 0.45 |
| >30–40 mm | 0.47 |
CEV = C + Mn/6 + (Cr + Mo + V)/5 + (Ni + Cu)/15, using mass percentages from the heat analysis. These are the GB/T 1591-2018 hot-rolled route values, not Q355N/Q355M limits. Restricted-silicon chemistry may invoke particular standard footnotes; no blanket increase has been applied to this table. A CEV ceiling is a composition control, not a weld procedure or an automatic no-preheat guarantee.
None of the listed I-section webs reaches 30 mm. On the ordinary web-based thickness reference they therefore remain in the ≤30 mm CEV band. The >30 mm row explains the material rule; it is not an offer of additional oversized sections or a reason to recalculate the tabulated web acceptance from the overall section depth.
GB/T 706-2016 dimensions and theoretical mass
All dimensions are millimetres; A is cross-sectional area in cm² and mass is kg/m. The values are a reference series, not a stock list or a guarantee that every size/grade combination can be supplied on a particular enquiry. Confirm the actual section, length, quantity and certification requirement. The tabulated mass is retained on its published 2016 basis rather than reconstructed from rounded area values. Dimensional, shape and mass tolerances must be taken from the contracted edition, not from the number of decimal places below.
Here h is the overall depth, b the flange width, d the web thickness and t the middle flange thickness. The inside face is tapered; t is not a constant plate thickness. The final column is an ordinary web-sampling yield reference, not a member resistance or a universal flange design value.
| Model | h × b × d | h mm | b mm | d mm | t mm | A cm² | kg/m | Web-band ReH min, MPa |
|---|---|---|---|---|---|---|---|---|
| 10 | 100×68×4.5 | 100 | 68.0 | 4.5 | 7.6 | 14.33 | 11.3 | 355 |
| 12 | 120×74×5 | 120 | 74.0 | 5.0 | 8.4 | 17.8 | 14.0 | 355 |
| 12.6 | 126×74×5 | 126 | 74.0 | 5.0 | 8.4 | 18.1 | 14.2 | 355 |
| 14 | 140×80×5.5 | 140 | 80.0 | 5.5 | 9.1 | 21.5 | 16.9 | 355 |
| 16 | 160×88×6 | 160 | 88.0 | 6.0 | 9.9 | 26.11 | 20.5 | 355 |
| 18 | 180×94×6.5 | 180 | 94.0 | 6.5 | 10.7 | 30.74 | 24.1 | 355 |
| 20a | 200×100×7 | 200 | 100.0 | 7.0 | 11.4 | 35.55 | 27.9 | 355 |
| 20b | 200×102×9 | 200 | 102.0 | 9.0 | 11.4 | 39.55 | 31.1 | 355 |
| 22a | 220×110×7.5 | 220 | 110.0 | 7.5 | 12.3 | 42.1 | 33.1 | 355 |
| 22b | 220×112×9.5 | 220 | 112.0 | 9.5 | 12.3 | 46.5 | 36.5 | 355 |
| 24a | 240×116×8 | 240 | 116.0 | 8.0 | 13.0 | 47.71 | 37.5 | 355 |
| 24b | 240×118×10 | 240 | 118.0 | 10.0 | 13.0 | 52.51 | 41.2 | 355 |
| 25a | 250×116×8 | 250 | 116.0 | 8.0 | 13.0 | 48.51 | 38.1 | 355 |
| 25b | 250×118×10 | 250 | 118.0 | 10.0 | 13.0 | 53.51 | 42.0 | 355 |
| 27a | 270×122×8.5 | 270 | 122.0 | 8.5 | 13.7 | 54.52 | 42.8 | 355 |
| 27b | 270×124×10.5 | 270 | 124.0 | 10.5 | 13.7 | 59.92 | 47.0 | 355 |
| 28a | 280×122×8.5 | 280 | 122.0 | 8.5 | 13.7 | 55.37 | 43.5 | 355 |
| 28b | 280×124×10.5 | 280 | 124.0 | 10.5 | 13.7 | 60.97 | 47.9 | 355 |
| 30a | 300×126×9 | 300 | 126.0 | 9.0 | 14.4 | 61.22 | 48.1 | 355 |
| 30b | 300×128×11 | 300 | 128.0 | 11.0 | 14.4 | 67.22 | 52.8 | 355 |
| 30c | 300×130×13 | 300 | 130.0 | 13.0 | 14.4 | 73.22 | 57.5 | 355 |
| 32a | 320×130×9.5 | 320 | 130.0 | 9.5 | 15.0 | 67.12 | 52.7 | 355 |
| 32b | 320×132×11.5 | 320 | 132.0 | 11.5 | 15.0 | 73.52 | 57.7 | 355 |
| 32c | 320×134×13.5 | 320 | 134.0 | 13.5 | 15.0 | 79.92 | 62.7 | 355 |
| 36a | 360×136×10 | 360 | 136.0 | 10.0 | 15.8 | 76.44 | 60.0 | 355 |
| 36b | 360×138×12 | 360 | 138.0 | 12.0 | 15.8 | 83.64 | 65.7 | 355 |
| 36c | 360×140×14 | 360 | 140.0 | 14.0 | 15.8 | 90.84 | 71.3 | 355 |
| 40a | 400×142×10.5 | 400 | 142.0 | 10.5 | 16.5 | 86.07 | 67.6 | 355 |
| 40b | 400×144×12.5 | 400 | 144.0 | 12.5 | 16.5 | 94.07 | 73.8 | 355 |
| 40c | 400×146×14.5 | 400 | 146.0 | 14.5 | 16.5 | 102.1 | 80.1 | 355 |
| 45a | 450×150×11.5 | 450 | 150.0 | 11.5 | 18.0 | 102.4 | 80.4 | 355 |
| 45b | 450×152×13.5 | 450 | 152.0 | 13.5 | 18.0 | 111.4 | 87.4 | 355 |
| 45c | 450×154×15.5 | 450 | 154.0 | 15.5 | 18.0 | 120.4 | 94.5 | 355 |
| 50a | 500×158×12 | 500 | 158.0 | 12.0 | 20.0 | 119.2 | 93.6 | 355 |
| 50b | 500×160×14 | 500 | 160.0 | 14.0 | 20.0 | 129.2 | 101.0 | 355 |
| 50c | 500×162×16 | 500 | 162.0 | 16.0 | 20.0 | 139.2 | 109.0 | 355 |
| 55a | 550×166×12.5 | 550 | 166.0 | 12.5 | 21.0 | 134.1 | 105.0 | 355 |
| 55b | 550×168×14.5 | 550 | 168.0 | 14.5 | 21.0 | 145.1 | 114.0 | 355 |
| 55c | 550×170×16.5 | 550 | 170.0 | 16.5 | 21.0 | 156.1 | 123.0 | 345 |
| 56a | 560×166×12.5 | 560 | 166.0 | 12.5 | 21.0 | 135.4 | 106.0 | 355 |
| 56b | 560×168×14.5 | 560 | 168.0 | 14.5 | 21.0 | 146.6 | 115.0 | 355 |
| 56c | 560×170×16.5 | 560 | 170.0 | 16.5 | 21.0 | 157.8 | 124.0 | 345 |
| 63a | 630×176×13 | 630 | 176.0 | 13.0 | 22.0 | 154.6 | 121.0 | 355 |
| 63b | 630×178×15 | 630 | 178.0 | 15.0 | 22.0 | 167.2 | 131.0 | 355 |
| 63c | 630×180×17 | 630 | 180.0 | 17.0 | 22.0 | 179.8 | 141.0 | 345 |
Inspection, traceability and enquiry
Check depth, flange width, web and middle-flange thickness, flange inclination, web alignment, straightness and end condition against the ordered section standard. Inspect the actual seating and clear root region where the connection depends on them.
- State the full designation, exact grade/material edition, dimensional edition, lengths and quantity; identify any approved deviation from the normal hot-rolled scope.
- Define the documentary requirement before ordering: heat analysis, applicable tensile results, the impact-test regime where required, and traceability between the certificate and supplied bundles. Do not assume a particular third-party certificate or inspection service.
- Specify theoretical or actual-mass settlement and any special dimensional acceptance before quotation. Extra tests, coatings, fabrication or additional delivery conditions are not implied by a general grade enquiry.
Lead time: a typical mill order is about 35 days. Stocked sizes: 1–3 days, subject to enquiry and confirmation of the individual size, grade, quantity and delivery requirement. A tabulated section is not a statement that it is held in stock.
Related section and material comparisons
For a different rolled geometry in the same material, see Q355B H-beams. The Q355B plate material page is a separate product form: it must not replace the section-specific sampling and shape requirements above.
For European parallel-flange alternatives, compare S355JR IPE dimensions and HEA/HEB sections. These are comparison pages, not declarations of material equivalence or interchangeable fit.
Compare this GB/T 706 tapered I-beam family in the other grade: Q235B I-Beams.
Frequently asked questions
Is a GB/T 706 I-beam the same as a GB H-beam or IPE?
No. This I-series has tapered inner flanges and its own widths, thicknesses, masses and tolerances. GB H-sections use GB/T 11263, while an IPE belongs to the European dimension system. A similar depth is not enough for substitution: compare section properties, seating, connection geometry and the specified material acceptance.
Does a model number such as 20 identify the whole beam?
No. State the suffix and complete dimensions. I20a is 200 × 100 × 7 mm with t = 11.4 mm; the b variant changes the web and flange width. Omitting a/b/c can change weight, connection clearance and resistance even if the overall depth stays the same.
Which thickness normally determines the tensile-test band?
GB/T 706-2016 Table 5 locates ordinary I-section specimens in the web. Use the applicable web thickness and GB/T 2975 specimen rules, not the 200 mm depth or an automatically selected flange thickness. If the contract changes sampling, agree the applicable material-thickness basis explicitly; do not extrapolate one test result to all local flange design checks.
Will a stronger or heavier beam cure lateral instability?
Not by itself. Lateral-torsional buckling depends on section geometry, unbraced length, restraint and load application. Weak-axis response also needs checking. A material upgrade or a thicker web does not create lateral restraint on the compression flange or correct an eccentric connection.
Is Q355B simply the new name for every Q345B product?
No. The 2018 material system replaced the older Q345 grade designation, but a historical certificate does not automatically meet every Q355B chemistry, thickness-band and toughness requirement. Compare the original order and actual test results. The hot-rolled route on this page is also distinct from Q355N and Q355M delivery conditions.
Does the 0.035% P/S table exclude all material above it?
Not unconditionally for sections. The hot-rolled Q355B table permits a +0.005 percentage-point allowance for sections and bars, giving 0.040% for each of P and S. If the project requires 0.035% without that allowance, state the tighter contractual requirement. Do not confuse heat maxima with finished-product analysis deviations.
Does Q355B guarantee 34 J in all directions and at low temperature?
No. The reference is 34 J longitudinal at +20 °C when testing applies. A 27 J transverse option requires agreement, and reduced-size specimen rules can change the applicable acceptance values. B quality does not establish subzero toughness. State the required test temperature, orientation, specimen basis and reporting rather than relying on the B suffix alone.
How should a welding and delivery enquiry be written?
Specify the exact section, Q355B to the hot-rolled GB/T 1591-2018 route, the GB/T 706 dimensional edition, length, quantity and test documentation. Include any restricted chemistry, CEV, actual impact test or finished-product analysis requirement. Provide joint details if welding suitability is being assessed. Typical mill orders are about 35 days; stocked sizes are 1–3 days only subject to individual enquiry confirmation.
For an enquiry to Gangsteel, provide the exact section and material specification, rather than a grade name alone. Quote acceptance remains subject to confirmation of the requested size, quantity and test scope.