A Q235B I-beam enquiry needs two independent decisions: the material is Q235B to GB/T 700, while the rolled I-section belongs to the tapered-flange series in GB/T 706. The number 235 is the minimum yield strength in the first material thickness band; it is neither a section depth nor a guaranteed bending capacity. The letter B identifies the material quality, including the specified room-temperature impact regime when testing is applicable.

This page is for Chinese rolled I-sections used where the drawing calls for that section family. The inner flange faces are inclined, unlike a parallel-flange H-beam or IPE. A depth-only request such as “200 mm Q235B beam” leaves out the flange width, web thickness and a/b/c variant needed to identify the product. Resolve those fields before a material comparison or a weight estimate.

Order identity: keep material and section standards separate
Order fieldScope
ProductQ235B taper-flange I-beams
Material standardGB/T 700-2006
Section/product standardGB/T 706: shape series, dimensions, tolerances and rolled-product requirements; numerical basis here 2016
Delivery conditionHot rolled; no normalized or TMCP route implied
CertificationIdentify grade, heat/batch traceability, dimensional edition and agreed test reporting

The numerical size tables on this page use GB/T 706-2016. On 22 November 2026 this is the effective edition. GB/T 706-2026 has been issued but does not take effect until 1 December 2026. These are not 2026-edition dimension tables. Specify the contractual dimensional edition, including its tolerances and mass basis, rather than silently applying a later edition to an earlier catalogue.

GB I20a tapered I-section with 200 mm depth, 100 mm flange width, 7 mm web, 11.4 mm middle flange thickness and 1:6 inner slope
GB I20a tapered I-section with 200 mm depth, 100 mm flange width, 7 mm web, 11.4 mm middle flange thickness and 1:6 inner slope. Fillet and toe radii are roll-pass-design references, not independent delivery acceptance criteria.

Selection and connection engineering

Identify the a/b/c variant before checking the connection

At a fixed depth, the suffix can change both flange width and web thickness. I20a is 200 × 100 × 7 mm with t = 11.4 mm, A = 35.55 cm² and 27.9 kg/m; I20b has a wider flange and a 9 mm web. Do not copy a bolt gauge or web-bearing detail from one variant to the other. Use the full h × b × d designation and retain t as a separate middle-flange measurement.

Treat a tapered flange as a seating problem, not a flat plate

The nominal inner slope is 1:6. A flat bolt washer or an attached plate can bear on a wedge-shaped surface rather than on a parallel seat. The detail designer should establish the required bearing surface, any compatible tapered washer and the permissible packing arrangement. Root fillets also reduce the clear flat space close to the web; outside flange width is not the available bolt platform.

Check bending about both axes and the unbraced length

A web-centred vertical load primarily uses the strong axis, but lateral load, an offset connection or an unrestrained compression flange can control before a simple section-yield calculation. Check weak-axis stiffness and lateral-torsional buckling with the actual lateral restraint and end conditions. A heavier b/c web is not a substitute for bracing, and a depth-only comparison with H-sections hides major flange-width differences.

Use mass for procurement without turning it into a test result

The I20a table mass gives 27.9 × 12 = 334.8 kg for a nominal 12 m piece before length and mass tolerances. This is a reference calculation, not a dispatch weight or an inventory promise. State whether the commercial settlement is theoretical or actual mass and which dimensional edition supplies the reference kg/m.

Mechanical properties: identify the tested thickness

Q235B section material: thickness bands covering every listed section
Nominal material thicknessMinimum ReH, MPaRm, MPaMinimum A, %
d ≤16 mm235370–50026
16 < d ≤40 mm225370–50026

For these tables d denotes the applicable material-thickness reference: ordinarily the web in I-sections/channels and the leg in angles. It is not the overall height or leg width. Elongation values are the section/bar longitudinal reference; plate-specific specimen orientation or deductions must not be imported unchanged. Final specimen position, direction and preparation follow the ordered standards and contract, including GB/T 2975. These two bands cover the supplied reference series; they do not authorize other heavy-section products.

Ordinary GB/T 706-2016 Table 5 sampling is from the web. The largest listed web is 17 mm; only models 55c, 56c and 63c exceed 16 mm and enter the second yield band. For example, I45a has an 18 mm middle flange but an 11.5 mm web. Do not use the flange automatically as the ordinary test-band selector, or treat a web acceptance result as a uniform local flange design strength.

Q235B impact quality, subject to test applicability
TemperatureLongitudinal Charpy V-notch referenceThickness and reporting qualification
+20 °C27 JOrdinary section test obligation starts at nominal thickness 12 mm; supplier-guaranteed omission below 25 mm requires buyer agreement.

Twenty of the 45 listed webs are at least 12 mm thick; the remaining 25 are below the ordinary thickness trigger. The B suffix is not proof that every delivered certificate contains measured impact results. Specify actual impact testing if required; use the standard’s applicable specimen and acceptance rules rather than assuming full-size specimens can be obtained from every section. B at +20 °C is not a subzero toughness qualification.

Heat chemistry and finished-product analysis

Material heat/ladle analysis: maxima in mass % unless stated otherwise
ElementLimitAcceptance note
C0.20A rise to 0.22 requires purchaser agreement; there is no carbon minimum in this edition.
Si0.35Heat-analysis maximum.
Mn1.40Maximum; do not impose the obsolete 0.30–0.70 range as the 2006 requirement.
P0.045Heat-analysis maximum.
S0.045Heat-analysis maximum.
Cr / Ni / Cu, each0.30Residual limits; analysis may be omitted when the supplier guarantees compliance.
N0.008Subject to the standard’s nitrogen/phosphorus compensation and nitrogen-binding exceptions; identify any applicable exception.
As0.080Ordinary maximum; arsenic-bearing ore arrangements require agreement.

These are material heat/ladle limits under GB/T 700-2006, not a finished-product analysis tolerance table. Q235B has no universal CEV ceiling in that standard. Where welding assessment requires carbon equivalent, agree the calculation and acceptance criterion using the actual heat chemistry rather than inventing a grade-wide cap.

Keep heat analysis and product analysis distinct. Heat/ladle results identify the melt; a test on the finished rolled section is product analysis and is assessed using the applicable GB/T 222 permitted-deviation provisions. No numerical product-analysis deviations are supplied by the compiled dataset, so no extra tolerance has been invented here. If product analysis is required, agree the sampling, test method, material edition and deviation table before ordering; do not add a discretionary percentage to every heat limit.

GB/T 706-2016 dimensions and theoretical mass

All dimensions are millimetres; A is cross-sectional area in cm² and mass is kg/m. The values are a reference series, not a stock list or a guarantee that every size/grade combination can be supplied on a particular enquiry. Confirm the actual section, length, quantity and certification requirement. The tabulated mass is retained on its published 2016 basis rather than reconstructed from rounded area values. Dimensional, shape and mass tolerances must be taken from the contracted edition, not from the number of decimal places below.

Here h is the overall depth, b the flange width, d the web thickness and t the middle flange thickness. The inside face is tapered; t is not a constant plate thickness. The final column is an ordinary web-sampling yield reference, not a member resistance or a universal flange design value.

Complete I-series, 45 models; GB/T 706-2016 reference
Modelh × b × dh mmb mmd mmt mmA cm²kg/mWeb-band ReH min, MPa
10100×68×4.510068.04.57.614.3311.3235
12120×74×512074.05.08.417.814.0235
12.6126×74×512674.05.08.418.114.2235
14140×80×5.514080.05.59.121.516.9235
16160×88×616088.06.09.926.1120.5235
18180×94×6.518094.06.510.730.7424.1235
20a200×100×7200100.07.011.435.5527.9235
20b200×102×9200102.09.011.439.5531.1235
22a220×110×7.5220110.07.512.342.133.1235
22b220×112×9.5220112.09.512.346.536.5235
24a240×116×8240116.08.013.047.7137.5235
24b240×118×10240118.010.013.052.5141.2235
25a250×116×8250116.08.013.048.5138.1235
25b250×118×10250118.010.013.053.5142.0235
27a270×122×8.5270122.08.513.754.5242.8235
27b270×124×10.5270124.010.513.759.9247.0235
28a280×122×8.5280122.08.513.755.3743.5235
28b280×124×10.5280124.010.513.760.9747.9235
30a300×126×9300126.09.014.461.2248.1235
30b300×128×11300128.011.014.467.2252.8235
30c300×130×13300130.013.014.473.2257.5235
32a320×130×9.5320130.09.515.067.1252.7235
32b320×132×11.5320132.011.515.073.5257.7235
32c320×134×13.5320134.013.515.079.9262.7235
36a360×136×10360136.010.015.876.4460.0235
36b360×138×12360138.012.015.883.6465.7235
36c360×140×14360140.014.015.890.8471.3235
40a400×142×10.5400142.010.516.586.0767.6235
40b400×144×12.5400144.012.516.594.0773.8235
40c400×146×14.5400146.014.516.5102.180.1235
45a450×150×11.5450150.011.518.0102.480.4235
45b450×152×13.5450152.013.518.0111.487.4235
45c450×154×15.5450154.015.518.0120.494.5235
50a500×158×12500158.012.020.0119.293.6235
50b500×160×14500160.014.020.0129.2101.0235
50c500×162×16500162.016.020.0139.2109.0235
55a550×166×12.5550166.012.521.0134.1105.0235
55b550×168×14.5550168.014.521.0145.1114.0235
55c550×170×16.5550170.016.521.0156.1123.0225
56a560×166×12.5560166.012.521.0135.4106.0235
56b560×168×14.5560168.014.521.0146.6115.0235
56c560×170×16.5560170.016.521.0157.8124.0225
63a630×176×13630176.013.022.0154.6121.0235
63b630×178×15630178.015.022.0167.2131.0235
63c630×180×17630180.017.022.0179.8141.0225

Inspection, traceability and enquiry

Check depth, flange width, web and middle-flange thickness, flange inclination, web alignment, straightness and end condition against the ordered section standard. Inspect the actual seating and clear root region where the connection depends on them.

  • State the full designation, exact grade/material edition, dimensional edition, lengths and quantity; identify any approved deviation from the normal hot-rolled scope.
  • Define the documentary requirement before ordering: heat analysis, applicable tensile results, the impact-test regime where required, and traceability between the certificate and supplied bundles. Do not assume a particular third-party certificate or inspection service.
  • Specify theoretical or actual-mass settlement and any special dimensional acceptance before quotation. Extra tests, coatings, fabrication or additional delivery conditions are not implied by a general grade enquiry.

Lead time: a typical mill order is about 35 days. Stocked sizes: 1–3 days, subject to enquiry and confirmation of the individual size, grade, quantity and delivery requirement. A tabulated section is not a statement that it is held in stock.

Related section and material comparisons

For a different rolled geometry in the same material, see Q235B H-beams. The Q235B plate material page is a separate product form: it must not replace the section-specific sampling and shape requirements above.

For European parallel-flange alternatives, compare S235JR IPE dimensions and HEA/HEB sections. These are comparison pages, not declarations of material equivalence or interchangeable fit.

Compare this GB/T 706 tapered I-beam family in the other grade: Q355B I-Beams.

Frequently asked questions

Is a GB/T 706 I-beam the same as a GB H-beam or IPE?

No. This I-series has tapered inner flanges and its own widths, thicknesses, masses and tolerances. GB H-sections use GB/T 11263, while an IPE belongs to the European dimension system. A similar depth is not enough for substitution: compare section properties, seating, connection geometry and the specified material acceptance.

Does a model number such as 20 identify the whole beam?

No. State the suffix and complete dimensions. I20a is 200 × 100 × 7 mm with t = 11.4 mm; the b variant changes the web and flange width. Omitting a/b/c can change weight, connection clearance and resistance even if the overall depth stays the same.

Which thickness normally determines the tensile-test band?

GB/T 706-2016 Table 5 locates ordinary I-section specimens in the web. Use the applicable web thickness and GB/T 2975 specimen rules, not the 200 mm depth or an automatically selected flange thickness. If the contract changes sampling, agree the applicable material-thickness basis explicitly; do not extrapolate one test result to all local flange design checks.

Will a stronger or heavier beam cure lateral instability?

Not by itself. Lateral-torsional buckling depends on section geometry, unbraced length, restraint and load application. Weak-axis response also needs checking. A material upgrade or a thicker web does not create lateral restraint on the compression flange or correct an eccentric connection.

Does Q235B always mean 235 MPa and a measured 27 J test?

No. Yield depends on the applicable material thickness; it is 235 MPa up to 16 mm and 225 MPa over 16 through 40 mm for the reference range here. The 27 J value is a +20 °C longitudinal impact requirement when the test regime applies. Thickness triggers and agreed supplier-guaranteed omissions must be considered before interpreting a certificate.

What if a finished-product chemistry test differs from the heat analysis?

First identify whether the result is a heat analysis or product analysis and which material edition and test method apply. Finished-product results use the applicable GB/T 222 permitted deviations; do not reject or accept them by silently adding a made-up allowance to the ladle table. Record the sampling and agreed acceptance basis before testing.

Can this grade be used in a welded or cold-service structure?

Neither application should be approved from the grade name alone. Welding needs actual heat chemistry, joint thickness, restraint and a suitable procedure; GB/T 700 does not supply a universal Q235B CEV ceiling. B quality is a room-temperature impact regime, not a subzero service guarantee. The project specification must set any additional toughness requirement.

What information should accompany a size enquiry?

Send the full section designation and variant, Q235B to GB/T 700-2006, the chosen GB/T 706 dimensional edition, lengths, quantity, mass-settlement basis and certificate/test requirements. Identify any actual impact testing or product analysis required. Typical mill orders are about 35 days; stocked sizes are 1–3 days only after the individual enquiry is confirmed.

For an enquiry to Gangsteel, provide the exact section and material specification, rather than a grade name alone. Quote acceptance remains subject to confirmation of the requested size, quantity and test scope.