EN 10025-2 S355JR HE A and HE B section profiles
Original generated illustration — schematic comparison of HE A and HE B sections, not a dimensioned drawing, stock photograph or material certificate.

 

What an S355JR HE Beam Order Specifies

S355JR is the 355 MPa grade of EN 10025-2 with the least demanding impact quality, tested at +20 °C. In HE A and HE B beams it is used where strength-governed members benefit from higher yield but low-temperature toughness is not specified. Enquiries to Gangsteel should state the exact HE designation and EN 10025-2 S355JR.

Two things set S355JR apart on HE sections: the yield band, which drops from 355 to 345 MPa above a 16 mm flange, and the carbon equivalent, which rises from 0.45% to 0.47% above 30 mm. Both are visible in the size tables below.

S355JR HE beam identity
Item Value for this product Comment
Material standard EN 10025-2:2019 Non-alloy structural steel, hot-rolled products
Steel name / number S355JR / 1.0045 Quality JR: impact test temperature in the table below
Section series and dimensions HE A and HE B to EN 10365:2017 Geometry and nominal mass only; no strength content
Shape and dimensional tolerances EN 10034 Acceptance of depth, width, thickness, squareness and straightness
General delivery requirements EN 10025-1 Testing, inspection documents and marking rules shared by the EN 10025 parts
Former designation Fe 510 B (EN 10025:1990) Historical reference only

HE A and HE B Sizes Read Through the S355JR Thickness Bands

EN 10365 fixes the geometry; EN 10025-2 fixes how strong the material must be at a given product thickness. For sections, tensile test pieces are normally taken from the flange, so the flange thickness tf is the practical reference for choosing the applicable S355JR band. The tables combine both: nominal HE A or HE B dimensions on the left, and on the right the minimum upper yield strength that the S355JR table requires at that flange thickness. The rows are reference geometry, not a stock list.

HE A (HEA): nominal dimensions with the S355JR yield band that applies at each flange thickness
Section h mm b mm tw mm tf mm kg/m Min. ReH MPa CEV max %
HE 100 A 96 100 5 8 16.7 355 0.45
HE 120 A 114 120 5 8 19.9 355 0.45
HE 140 A 133 140 5.5 8.5 24.7 355 0.45
HE 160 A 152 160 6 9 30.4 355 0.45
HE 180 A 171 180 6 9.5 35.5 355 0.45
HE 200 A 190 200 6.5 10 42.3 355 0.45
HE 220 A 210 220 7 11 50.5 355 0.45
HE 240 A 230 240 7.5 12 60.3 355 0.45
HE 260 A 250 260 7.5 12.5 68.2 355 0.45
HE 280 A 270 280 8 13 76.4 355 0.45
HE 300 A 290 300 8.5 14 88.3 355 0.45
HE 320 A 310 300 9 15.5 97.6 355 0.45
HE 340 A 330 300 9.5 16.5 105 345 0.45
HE 360 A 350 300 10 17.5 112 345 0.45
HE 400 A 390 300 11 19 125 345 0.45
HE 450 A 440 300 11.5 21 140 345 0.45
HE 500 A 490 300 12 23 155 345 0.45
HE 550 A 540 300 12.5 24 166 345 0.45
HE 600 A 590 300 13 25 178 345 0.45
HE 650 A 640 300 13.5 26 190 345 0.45
HE 700 A 690 300 14.5 27 204 345 0.45
HE 800 A 790 300 15 28 224 345 0.45
HE 900 A 890 300 16 30 252 345 0.45
HE 1000 A 990 300 16.5 31 272 345 0.47
HE B (HEB): nominal dimensions with the S355JR yield band that applies at each flange thickness
Section h mm b mm tw mm tf mm kg/m Min. ReH MPa CEV max %
HE 100 B 100 100 6 10 20.4 355 0.45
HE 120 B 120 120 6.5 11 26.7 355 0.45
HE 140 B 140 140 7 12 33.7 355 0.45
HE 160 B 160 160 8 13 42.6 355 0.45
HE 180 B 180 180 8.5 14 51.2 355 0.45
HE 200 B 200 200 9 15 61.3 355 0.45
HE 220 B 220 220 9.5 16 71.5 355 0.45
HE 240 B 240 240 10 17 83.2 345 0.45
HE 260 B 260 260 10 17.5 93.0 345 0.45
HE 280 B 280 280 10.5 18 103 345 0.45
HE 300 B 300 300 11 19 117 345 0.45
HE 320 B 320 300 11.5 20.5 127 345 0.45
HE 340 B 340 300 12 21.5 134 345 0.45
HE 360 B 360 300 12.5 22.5 142 345 0.45
HE 400 B 400 300 13.5 24 155 345 0.45
HE 450 B 450 300 14 26 171 345 0.45
HE 500 B 500 300 14.5 28 187 345 0.45
HE 550 B 550 300 15 29 199 345 0.45
HE 600 B 600 300 15.5 30 212 345 0.45
HE 650 B 650 300 16 31 225 345 0.47
HE 700 B 700 300 17 32 241 345 0.47
HE 800 B 800 300 17.5 33 262 345 0.47
HE 900 B 900 300 18.5 35 291 345 0.47
HE 1000 B 1000 300 19 36 314 345 0.47

h is overall depth, b flange width, tw web thickness and tf flange thickness; kg/m is nominal mass. HE A is the lighter series for the same serial size and HE B the heavier one: HE 300 A is 290 mm deep with a 14 mm flange, while HE 300 B is 300 mm deep with a 19 mm flange. Order the full designation, because a drawing note such as “H300” does not distinguish them.

For S355JR, HE 100 A to HE 320 A and HE 100 B to HE 220 B are in the 355 MPa band; larger sizes are at 345 MPa. The CEV maximum is 0.45% for flanges up to 30 mm and 0.47% above: in the listed series this affects HE 1000 A (31 mm) and HE 650 B to HE 1000 B (31–36 mm). Carbon remains 0.24% throughout.

S355JR Chemical Composition for HE Sections

S355JR heat (ladle) analysis, maximum mass % unless stated
Element Maximum How it applies to HE A / HE B
C 0.24 Same maximum in every thickness band up to 100 mm
Si 0.55 —
Mn 1.60 —
P 0.040 0.035 may be agreed with the galvanizing silicon option
S 0.040 —
N 0.012 Waived with total Al ≥ 0.020% or sufficient reported nitrogen-binding elements
Cu 0.55 —
CEV 0.45 / 0.47 0.45 up to 30 mm; 0.47 for 30 mm < t ≤ 40 mm. Special S355 provisions of clause 7.2.5 apply where invoked

S355JR has the highest carbon allowance of the 355 grades (0.24%), and the JR quality does not require fully killed practice in the way J2 does. Phosphorus and sulfur are each limited to 0.040%. The nitrogen limit of 0.012% is waived only where enough aluminium or other nitrogen-binding elements are present and reported.

CEV = C + Mn/6 + (Cr + Mo + V)/5 + (Cu + Ni)/15, using heat-analysis values. Additional elements, if added, must be stated on the inspection document. These are limits for acceptance, not the composition of any particular heat.

S355JR Mechanical Properties by Flange Thickness

S355JR longitudinal tensile and impact requirements for HE sections
Property tf ≤ 16 mm 16 mm < tf ≤ 40 mm
Minimum upper yield strength ReH 355 MPa 345 MPa
Tensile strength Rm 470–630 MPa 470–630 MPa
Minimum elongation A, L0 = 5.65√S0 22% 22%
Charpy V-notch, minimum 27 J at +20 °C 27 J at +20 °C

The +20 °C impact quality is the main reason designers move from S355JR to S355J0 or S355J2 for external or cold-climate structures. JR material is commonly ordered for internal, heated buildings; the choice belongs to the design engineer and the applicable code.

How S355JR Differs from Neighbouring EN 10025-2 Grades

S355JR against related grades
Grade Key difference from S355JR Ordering consequence
S355J0 Impact test at 0 °C; C 0.20/0.22%; P and S 0.035% Colder test and tighter chemistry
S355J2 Impact test at −20 °C; fully killed; P and S 0.030%; C 0.20/0.22% A JR certificate cannot satisfy a J2 order
S275JR Yield 275/265 MPa; CEV 0.40% Lower resistance; different design values
ASTM A992 Different standard family with a yield range of 50–65 ksi and Fy/Fu control Not an equivalent label; see ASTM A992 wide flange W-beams for that material

Strength class alone does not make grades interchangeable. The impact quality, chemistry and certificate requirements are part of the specification.

Welding, Cutting and Galvanizing Notes

With CEV up to 0.45–0.47%, S355JR HE beams need more attention to welding procedure than S235 or S275: preheat may be required for thick flanges, high restraint or low heat input, according to the welding standard and consumable data. The higher carbon allowance compared with S355J2 also matters for hardness in the heat-affected zone. Thermal cutting edges of thick flanges may need preparation before welding. The galvanizing chemistry option is available as for the other JR grades.

Delivery Condition, Heat Treatment and Inspection

Items to state for an S355JR HE beam order
Item What to specify Why it matters
Delivery condition As-rolled (+AR) or normalized / normalizing rolled (+N) where the order requires it The grade name alone does not fix the delivery condition; +N must be ordered explicitly
Heat treatment after delivery Normally none for rolled HE beams; any hot forming or stress relief needs an agreed procedure Uncontrolled heating can alter the certified properties
Impact verification State whether the 27 J at +20 °C test is to be verified and reported Avoids a certificate that lists the grade but no Charpy result
Inspection document EN 10204 type, typically 3.1 when specific test results are required Results must be traceable to the heat and the delivered pieces
Dimensional acceptance EN 10034 tolerances, length tolerance and cut-length list Nominal table values are not tolerance limits

Where the CEV of thicker HE B sizes matters to the welding procedure, ask for the actual heat CEV on the certificate rather than relying on the maximum.

RFQ Checklist for S355JR HEA and HEB Beams

  • Full section designation, for example HE 300 B, not “H300”.
  • Material as EN 10025-2 S355JR, with delivery condition and any options such as galvanizing chemistry.
  • Lengths, quantities and total mass basis (theoretical or weighed).
  • Impact verification, EN 10204 document type and heat traceability.
  • Cutting, drilling, blasting or coating drawings, packing and destination.

Typical lead time is about 35 days for mill orders; sizes available from stock can ship in 1-3 days. Stock availability by size is confirmed at enquiry; the tables on this page are reference geometry, not a stock list.

For flat components in the same structure, order EN 10025-2 S355JR steel plate separately; plate and section certificates are issued per product. For the narrow-flange alternative see the EN 10365 IPE beam range with EN 10025-2 grades, and for heavier column sections the universal column (UC) range. The structural steel sections selection guide compares the families.

Other EN 10025-2 grades in the same HE A / HE B series: S235JR HEA and HEB beams, S275JR HEA and HEB beams, S355J2 HEA and HEB beams.

Frequently Asked Questions

Why does the S355JR CEV limit change within the HE B series?

EN 10025-2 sets a CEV maximum of 0.45% up to 30 mm and 0.47% for 30 mm to 40 mm. HE 650 B to HE 1000 B have flanges of 31 to 36 mm, so the higher limit applies to them, as it does to HE 1000 A.

Is S355JR suitable for outdoor steelwork?

It depends on the service temperature and the design code. JR is tested at +20 °C only. For structures exposed to low temperatures, engineers often specify S355J0 or S355J2. The decision belongs to the designer, not to the supplier.

What is the difference between S355JR and S355J2 HE beams?

The strength requirements are the same, but J2 is impact-tested at minus 20 °C, is fully killed with nitrogen-binding elements, and has tighter phosphorus and sulfur limits and a lower carbon maximum. The certificates are not interchangeable.

At which sizes is S355JR yield 345 MPa?

Where the flange exceeds 16 mm: HE 340 A and larger, and HE 240 B and larger. Design and acceptance should use the band that matches the flange thickness.

Is S355JR equivalent to ASTM A992?

No. They belong to different standard systems with different chemistry, tensile and impact requirements. A992 has a yield range and yield-to-tensile limit that S355JR does not; S355JR has an EN impact quality that A992 does not define in the same way. A project must order the specified standard.

Does S355JR need preheat for welding?

Not always. The need depends on CEV, flange thickness, joint restraint, heat input and hydrogen control, assessed under the welding standard used. Thick HE B flanges at the 0.47% CEV level are more likely to need preheat than thin HE A flanges.

What should the S355JR certificate show?

The standard and grade, heat number, chemistry including CEV, tensile results from the appropriate location, any ordered impact results at +20 °C, the section designation and the EN 10204 document type. Check that the heat matches the delivered pieces.

Other Products