EN 10025-2 S275JR IPE 200, IPE 400 and IPE 600 cross-sections drawn to the same scale
Original generated illustration — IPE 200, IPE 400 and IPE 600 at the same scale; schematic only, not a dimensioned drawing, stock photograph or material certificate.

 

S275JR IPE Beams: Grade and Section in One Order

S275JR IPE beams combine the EN 10365 IPE series with the intermediate EN 10025-2 grade: 275 MPa minimum yield for flanges up to 16 mm and a +20 °C impact quality. Gangsteel supplies S275JR IPE for floor beams, roof beams and frame members where S235 would need a deeper section but the welding and cost profile of S355 is not wanted. Order it as “IPE 330, EN 10025-2 S275JR”.

S275JR IPE beam specification
Item Value Note
Material EN 10025-2:2019 S275JR (1.0044) Impact quality 27 J at +20 °C
Section series IPE to EN 10365:2017 Standard IPE 80–600; IPE A, IPE O and IPE V variants are separate series
Tolerances EN 10034 Depth, width, thickness, out-of-square, straightness
General delivery EN 10025-1 Testing, inspection documents, marking
Supply Gangsteel supplies EN 10025-2 S275JR IPE beams Sizes, quantities and stock confirmed per enquiry
Former designation St 44-2 (DIN 17100, withdrawn) Historical only

IPE 80 to IPE 600 in S275JR

Standard IPE 80–600 in S275JR: nominal geometry, applicable yield band, characteristic plastic moment and cross-section class in pure compression
IPE h mm b mm tw mm tf mm kg/m ReH MPa Wpl,y cm³ Wpl,y·ReH kNm Class, axial
IPE 80 80.0 46.0 3.8 5.2 6.0 275 23.2 6 Class 1
IPE 100 100.0 55.0 4.1 5.7 8.1 275 39.4 11 Class 1
IPE 120 120.0 64.0 4.4 6.3 10.4 275 60.7 17 Class 1
IPE 140 140.0 73.0 4.7 6.9 12.9 275 88.3 24 Class 1
IPE 160 160.0 82.0 5.0 7.4 15.8 275 124 34 Class 1
IPE 180 180.0 91.0 5.3 8.0 18.8 275 166 46 Class 1
IPE 200 200.0 100.0 5.6 8.5 22.4 275 221 61 Class 1
IPE 220 220.0 110.0 5.9 9.2 26.2 275 285 78 Class 1
IPE 240 240.0 120.0 6.2 9.8 30.7 275 367 101 Class 2
IPE 270 270.0 135.0 6.6 10.2 36.1 275 484 133 Class 2
IPE 300 300.0 150.0 7.1 10.7 42.2 275 628 173 Class 2
IPE 330 330.0 160.0 7.5 11.5 49.1 275 804 221 Class 3
IPE 360 360.0 170.0 8.0 12.7 57.1 275 1,020 280 Class 3
IPE 400 400.0 180.0 8.6 13.5 66.3 275 1,310 360 Class 3
IPE 450 450.0 190.0 9.4 14.6 77.6 275 1,700 468 Class 4
IPE 500 500.0 200.0 10.2 16.0 90.7 275 2,190 602 Class 4
IPE 550 550.0 210.0 11.1 17.2 106 265 2,790 739 Class 4
IPE 600 600.0 220.0 12.0 19.0 122 265 3,510 930 Class 4

IPE 80 to IPE 500 are in the 275 MPa band; IPE 550 and IPE 600 (flanges 17.2 and 19.0 mm) drop to 265 MPa. The higher yield reduces ε to 0.92, so the slender webs of the deeper IPE sizes reach higher compression classes than in S235JR: 8 of 18 sizes remain Class 1 in pure compression. In bending, all remain Class 1.

Wpl,y·ReH is the characteristic plastic moment of the cross-section about the major axis, using the S275JR yield band for that flange thickness. It is a cross-section value only: it excludes partial factors, lateral-torsional buckling, shear interaction and serviceability, and is not a safe working load. The class column applies the EN 1993-1-1 width-to-thickness limits for pure axial compression with ε = √(235/ReH); in pure major-axis bending every standard IPE in this grade is Class 1. Confirm classification with the design code and national annex used on the project.

S275JR Chemistry Limits Relevant to IPE

S275JR heat analysis, maximum mass % (IPE flanges are all below 30 mm)
Element Limit
C 0.21
Mn 1.50
Si no maximum in grade row
P 0.040
S 0.040
N 0.012 (waived with total Al ≥ 0.020% or reported N-binding elements)
Cu 0.55
CEV 0.40

Carbon is limited to 0.21% and CEV to 0.40% throughout the IPE range. EN 10025-2:2019 clause 7.2.5 contains special S275 provisions that the purchaser may invoke; quote them in the order if required. The galvanizing silicon option applies as for the other JR grades.

S275JR Tensile and Impact Requirements

S275JR longitudinal properties for IPE sections
Property tf ≤ 16 mm (IPE 80–500) 16 mm < tf ≤ 40 mm (IPE 550, 600)
Minimum ReH 275 MPa 265 MPa
Rm 410–560 MPa 410–560 MPa
Minimum A (L0 = 5.65√S0) 23% 23%
Charpy V, minimum 27 J at +20 °C 27 J at +20 °C

The 23% elongation and 410–560 MPa tensile range are specific to S275. For IPE 80 and IPE 100, whose flanges are 5.2 and 5.7 mm, full-size Charpy specimens cannot be taken; the EN 10025 specimen-size and minimum-thickness rules decide whether and how the +20 °C result is reported.

Design Notes Specific to S275JR IPE Members

For laterally restrained floor beams, S275 increases the usable bending resistance by about 17% over S235 in the same IPE size, which can allow one serial size smaller where deflection is not governing. For unrestrained beams the gain is smaller because lateral-torsional buckling depends on stiffness as well as yield. The characteristic plastic moment of IPE 360 in S275JR is about 280 kNm (1,020 cm³ × 275 MPa).

S275JR Compared with Other IPE Grades

S275JR IPE against other grades
Grade IPE 360 Wpl,y·ReH Difference that matters
S235JR about 240 kNm Lower resistance; CEV 0.35%
S275JR about 280 kNm Intermediate strength; CEV 0.40%
S355JR about 362 kNm Higher resistance; CEV 0.45%
S275J0 / S275J2 about 280 kNm Same strength, colder impact test and tighter P and S; C limit 0.18%

Fabrication: Welding, Cutting and Coating

A CEV of 0.40% keeps S275JR IPE easy to weld with ordinary procedures; with flanges no thicker than 19 mm, preheat is rarely driven by thickness alone, although restraint and hydrogen control still matter. Thermal cutting and drilling behave as for S235. Where members are galvanized, agree the silicon option and consider distortion of long, thin-webbed IPE sections.

Delivery Condition, Inspection and Lead Time

What to state on an S275JR IPE order
Item Specify Reason
Delivery condition +AR or +N where required Not implied by the grade name
Impact test Whether the 27 J at +20 °C result must be reported, and specimen size for thin flanges Thin IPE flanges limit specimen size
Inspection document EN 10204 3.1 for heat-specific results Traceability to the delivered pieces
Dimensions EN 10034 tolerances, lengths and cut list Nominal values are not tolerances
Mass basis Theoretical or weighed Avoids invoicing disputes

Lead time: typical delivery is about 35 days for mill orders, and sizes available from stock can ship in 1–3 days. Stock availability is confirmed size by size at enquiry; the IPE table on this page is reference geometry, not a stock list.

RFQ Checklist

  • Full designation such as IPE 300, quantity and lengths.
  • EN 10025-2 S275JR with delivery condition and any chemistry options.
  • Impact verification and EN 10204 document type.
  • Processing (cutting, drilling, blasting, priming), packing and destination.
  • Whether stock sizes are preferred for 1–3 day dispatch or a mill order is acceptable.

For heavier wide-flange alternatives in the same grade see EN 10025-2 S275JR HEA and HEB beams. The IPE beam size range and grade overview summarises the IPE series across grades, and connection plates are covered by EN 10025-2 S275JR steel plate. The structural steel sections guide compares section families.

The same IPE series in other EN 10025-2 grades: S235JR IPE beams, S355JR IPE beams, S355J2 IPE beams.

Frequently Asked Questions

Does Gangsteel supply S275JR IPE beams?

Yes. Gangsteel supplies EN 10025-2 S275JR IPE beams. Stock is confirmed size by size at enquiry; stock sizes can ship in 1 to 3 days, and mill orders typically take about 35 days.

At which IPE sizes does S275JR yield fall to 265 MPa?

At IPE 550 and IPE 600, whose flanges exceed 16 mm. All smaller IPE sizes are rated at 275 MPa.

Why choose S275JR rather than S355JR for IPE floor beams?

When deflection or lateral-torsional buckling limits the design, the extra strength of S355 is only partly usable, while S275 keeps a lower CEV and simpler welding. Where strength governs, S355 may allow a lighter section. The engineer decides.

Are the S275 special provisions automatic?

No. Clause 7.2.5 of EN 10025-2:2019 lists provisions the purchaser may invoke for S275. If needed, they must be written into the purchase order and checked on the inspection certificate.

Do deeper IPE sections change class in S275JR?

In pure axial compression the slender webs of deeper IPE sizes move into higher classes as ε falls with yield strength. In major-axis bending all standard IPE sizes stay Class 1 in S275. Use the design code to confirm classification for combined loading.

Can S275JR IPE be impact tested?

Yes, at +20 °C, where flange thickness allows a valid specimen. For the smallest sizes the standard specimen-size rules apply, so agree reporting in the order.

What should be on the S275JR IPE certificate?

The standard and grade, heat number, chemistry including CEV, tensile results, any ordered impact results, the IPE designation and the EN 10204 type, typically 3.1. Any invoked clause 7.2.5 requirements should also be shown.