Steel Beams
EN 10025-2 S275JR IPE Beams: Sizes & Properties

S275JR IPE Beams: Grade and Section in One Order
S275JR IPE beams combine the EN 10365 IPE series with the intermediate EN 10025-2 grade: 275 MPa minimum yield for flanges up to 16 mm and a +20 °C impact quality. Gangsteel supplies S275JR IPE for floor beams, roof beams and frame members where S235 would need a deeper section but the welding and cost profile of S355 is not wanted. Order it as “IPE 330, EN 10025-2 S275JR”.
| Item | Value | Note |
|---|---|---|
| Material | EN 10025-2:2019 S275JR (1.0044) | Impact quality 27 J at +20 °C |
| Section series | IPE to EN 10365:2017 | Standard IPE 80–600; IPE A, IPE O and IPE V variants are separate series |
| Tolerances | EN 10034 | Depth, width, thickness, out-of-square, straightness |
| General delivery | EN 10025-1 | Testing, inspection documents, marking |
| Supply | Gangsteel supplies EN 10025-2 S275JR IPE beams | Sizes, quantities and stock confirmed per enquiry |
| Former designation | St 44-2 (DIN 17100, withdrawn) | Historical only |
IPE 80 to IPE 600 in S275JR
| IPE | h mm | b mm | tw mm | tf mm | kg/m | ReH MPa | Wpl,y cm³ | Wpl,y·ReH kNm | Class, axial |
|---|---|---|---|---|---|---|---|---|---|
| IPE 80 | 80.0 | 46.0 | 3.8 | 5.2 | 6.0 | 275 | 23.2 | 6 | Class 1 |
| IPE 100 | 100.0 | 55.0 | 4.1 | 5.7 | 8.1 | 275 | 39.4 | 11 | Class 1 |
| IPE 120 | 120.0 | 64.0 | 4.4 | 6.3 | 10.4 | 275 | 60.7 | 17 | Class 1 |
| IPE 140 | 140.0 | 73.0 | 4.7 | 6.9 | 12.9 | 275 | 88.3 | 24 | Class 1 |
| IPE 160 | 160.0 | 82.0 | 5.0 | 7.4 | 15.8 | 275 | 124 | 34 | Class 1 |
| IPE 180 | 180.0 | 91.0 | 5.3 | 8.0 | 18.8 | 275 | 166 | 46 | Class 1 |
| IPE 200 | 200.0 | 100.0 | 5.6 | 8.5 | 22.4 | 275 | 221 | 61 | Class 1 |
| IPE 220 | 220.0 | 110.0 | 5.9 | 9.2 | 26.2 | 275 | 285 | 78 | Class 1 |
| IPE 240 | 240.0 | 120.0 | 6.2 | 9.8 | 30.7 | 275 | 367 | 101 | Class 2 |
| IPE 270 | 270.0 | 135.0 | 6.6 | 10.2 | 36.1 | 275 | 484 | 133 | Class 2 |
| IPE 300 | 300.0 | 150.0 | 7.1 | 10.7 | 42.2 | 275 | 628 | 173 | Class 2 |
| IPE 330 | 330.0 | 160.0 | 7.5 | 11.5 | 49.1 | 275 | 804 | 221 | Class 3 |
| IPE 360 | 360.0 | 170.0 | 8.0 | 12.7 | 57.1 | 275 | 1,020 | 280 | Class 3 |
| IPE 400 | 400.0 | 180.0 | 8.6 | 13.5 | 66.3 | 275 | 1,310 | 360 | Class 3 |
| IPE 450 | 450.0 | 190.0 | 9.4 | 14.6 | 77.6 | 275 | 1,700 | 468 | Class 4 |
| IPE 500 | 500.0 | 200.0 | 10.2 | 16.0 | 90.7 | 275 | 2,190 | 602 | Class 4 |
| IPE 550 | 550.0 | 210.0 | 11.1 | 17.2 | 106 | 265 | 2,790 | 739 | Class 4 |
| IPE 600 | 600.0 | 220.0 | 12.0 | 19.0 | 122 | 265 | 3,510 | 930 | Class 4 |
IPE 80 to IPE 500 are in the 275 MPa band; IPE 550 and IPE 600 (flanges 17.2 and 19.0 mm) drop to 265 MPa. The higher yield reduces ε to 0.92, so the slender webs of the deeper IPE sizes reach higher compression classes than in S235JR: 8 of 18 sizes remain Class 1 in pure compression. In bending, all remain Class 1.
Wpl,y·ReH is the characteristic plastic moment of the cross-section about the major axis, using the S275JR yield band for that flange thickness. It is a cross-section value only: it excludes partial factors, lateral-torsional buckling, shear interaction and serviceability, and is not a safe working load. The class column applies the EN 1993-1-1 width-to-thickness limits for pure axial compression with ε = √(235/ReH); in pure major-axis bending every standard IPE in this grade is Class 1. Confirm classification with the design code and national annex used on the project.
S275JR Chemistry Limits Relevant to IPE
| Element | Limit |
|---|---|
| C | 0.21 |
| Mn | 1.50 |
| Si | no maximum in grade row |
| P | 0.040 |
| S | 0.040 |
| N | 0.012 (waived with total Al ≥ 0.020% or reported N-binding elements) |
| Cu | 0.55 |
| CEV | 0.40 |
Carbon is limited to 0.21% and CEV to 0.40% throughout the IPE range. EN 10025-2:2019 clause 7.2.5 contains special S275 provisions that the purchaser may invoke; quote them in the order if required. The galvanizing silicon option applies as for the other JR grades.
S275JR Tensile and Impact Requirements
| Property | tf ≤ 16 mm (IPE 80–500) | 16 mm < tf ≤ 40 mm (IPE 550, 600) |
|---|---|---|
| Minimum ReH | 275 MPa | 265 MPa |
| Rm | 410–560 MPa | 410–560 MPa |
| Minimum A (L0 = 5.65√S0) | 23% | 23% |
| Charpy V, minimum | 27 J at +20 °C | 27 J at +20 °C |
The 23% elongation and 410–560 MPa tensile range are specific to S275. For IPE 80 and IPE 100, whose flanges are 5.2 and 5.7 mm, full-size Charpy specimens cannot be taken; the EN 10025 specimen-size and minimum-thickness rules decide whether and how the +20 °C result is reported.
Design Notes Specific to S275JR IPE Members
For laterally restrained floor beams, S275 increases the usable bending resistance by about 17% over S235 in the same IPE size, which can allow one serial size smaller where deflection is not governing. For unrestrained beams the gain is smaller because lateral-torsional buckling depends on stiffness as well as yield. The characteristic plastic moment of IPE 360 in S275JR is about 280 kNm (1,020 cm³ × 275 MPa).
S275JR Compared with Other IPE Grades
| Grade | IPE 360 Wpl,y·ReH | Difference that matters |
|---|---|---|
| S235JR | about 240 kNm | Lower resistance; CEV 0.35% |
| S275JR | about 280 kNm | Intermediate strength; CEV 0.40% |
| S355JR | about 362 kNm | Higher resistance; CEV 0.45% |
| S275J0 / S275J2 | about 280 kNm | Same strength, colder impact test and tighter P and S; C limit 0.18% |
Fabrication: Welding, Cutting and Coating
A CEV of 0.40% keeps S275JR IPE easy to weld with ordinary procedures; with flanges no thicker than 19 mm, preheat is rarely driven by thickness alone, although restraint and hydrogen control still matter. Thermal cutting and drilling behave as for S235. Where members are galvanized, agree the silicon option and consider distortion of long, thin-webbed IPE sections.
Delivery Condition, Inspection and Lead Time
| Item | Specify | Reason |
|---|---|---|
| Delivery condition | +AR or +N where required | Not implied by the grade name |
| Impact test | Whether the 27 J at +20 °C result must be reported, and specimen size for thin flanges | Thin IPE flanges limit specimen size |
| Inspection document | EN 10204 3.1 for heat-specific results | Traceability to the delivered pieces |
| Dimensions | EN 10034 tolerances, lengths and cut list | Nominal values are not tolerances |
| Mass basis | Theoretical or weighed | Avoids invoicing disputes |
Lead time: typical delivery is about 35 days for mill orders, and sizes available from stock can ship in 1–3 days. Stock availability is confirmed size by size at enquiry; the IPE table on this page is reference geometry, not a stock list.
RFQ Checklist
- Full designation such as IPE 300, quantity and lengths.
- EN 10025-2 S275JR with delivery condition and any chemistry options.
- Impact verification and EN 10204 document type.
- Processing (cutting, drilling, blasting, priming), packing and destination.
- Whether stock sizes are preferred for 1–3 day dispatch or a mill order is acceptable.
For heavier wide-flange alternatives in the same grade see EN 10025-2 S275JR HEA and HEB beams. The IPE beam size range and grade overview summarises the IPE series across grades, and connection plates are covered by EN 10025-2 S275JR steel plate. The structural steel sections guide compares section families.
The same IPE series in other EN 10025-2 grades: S235JR IPE beams, S355JR IPE beams, S355J2 IPE beams.
Frequently Asked Questions
Does Gangsteel supply S275JR IPE beams?
Yes. Gangsteel supplies EN 10025-2 S275JR IPE beams. Stock is confirmed size by size at enquiry; stock sizes can ship in 1 to 3 days, and mill orders typically take about 35 days.
At which IPE sizes does S275JR yield fall to 265 MPa?
At IPE 550 and IPE 600, whose flanges exceed 16 mm. All smaller IPE sizes are rated at 275 MPa.
Why choose S275JR rather than S355JR for IPE floor beams?
When deflection or lateral-torsional buckling limits the design, the extra strength of S355 is only partly usable, while S275 keeps a lower CEV and simpler welding. Where strength governs, S355 may allow a lighter section. The engineer decides.
Are the S275 special provisions automatic?
No. Clause 7.2.5 of EN 10025-2:2019 lists provisions the purchaser may invoke for S275. If needed, they must be written into the purchase order and checked on the inspection certificate.
Do deeper IPE sections change class in S275JR?
In pure axial compression the slender webs of deeper IPE sizes move into higher classes as ε falls with yield strength. In major-axis bending all standard IPE sizes stay Class 1 in S275. Use the design code to confirm classification for combined loading.
Can S275JR IPE be impact tested?
Yes, at +20 °C, where flange thickness allows a valid specimen. For the smallest sizes the standard specimen-size rules apply, so agree reporting in the order.
What should be on the S275JR IPE certificate?
The standard and grade, heat number, chemistry including CEV, tensile results, any ordered impact results, the IPE designation and the EN 10204 type, typically 3.1. Any invoked clause 7.2.5 requirements should also be shown.