Steel Channels
SS400 Channels: JIS G 3192 Sizes & Material Properties
SS400 JIS channels combine a general-structure material grade with a specific open, tapered-flange cross-section. JIS G 3101 governs the material; JIS G 3192 governs the channel dimensions, mass, shape and their permitted variations. A channel 200 × 80 × 7.5 × 11 is therefore a different product from a 200 mm PFC, UPE, UPN or GB channel selected by depth alone.
The open section makes the load path particularly important. A load on one flange or an eccentric bracket can cause twist alongside bending, and a pair of channels only develops the assumed combined behaviour when its connections transfer the required forces. SS400 chemistry and tensile acceptance do not certify the stability of a built-up channel assembly. The 16 reference sizes below are identification data, not a stock or fabrication-service statement.
| Order field | Defined scope |
|---|---|
| Product | hot-rolled tapered-flange channels |
| Material | JIS G 3101:2024 SS400, rolled steels for general structure |
| Dimensions/product form | JIS G 3192:2024, hot-rolled sections: shape, dimensions, mass, appearance and permitted variations |
| Sampling/testing | JIS G 0416 sample location/preparation; relevant JIS tensile/bend test methods |
| Delivery/document | Hot-rolled section; actual condition and inspection-document requirements identified on the order |
Edition check: the JSA catalogue lists JIS G 3101:2024, issued 20 February 2024, and JIS G 3192:2024, issued 20 November 2024, as valid. This page uses those editions rather than an assumed 2026 revision. The contract must name the applicable material and dimensional editions; a current title does not justify silently mixing old and new radius or mass data.
Section selection and connection engineering
Recognize the JIS taper and measurement point
The reference inner flange/web angle is 95°, a 5° incline from horizontal. t2 is measured halfway across the clear outstand, at (B−t1)/2 inward from the toe. For 200 × 80 × 7.5 × 11, the root radius is 12 mm and the toe radius 6 mm. This geometry is not the GB1:10 channel convention or a parallel-flange PFC connection surface.
Follow the load through the open section
The centroid and shear centre of a channel do not generally coincide. The location of a transverse load relative to the shear centre affects torsion, while a flange-mounted bracket can add local flange bending and overall weak-axis response. Show the load line, member orientation and restraint in the design model. A strong-axis stress check alone can miss the controlling deformation or instability.
Make paired-channel action an engineered assumption
Back-to-back, toe-to-toe and separated channel arrangements need different connection details. Spacers, battens or stitch connections and end load introduction must transfer the forces needed for combined action. Do not treat two loose channels as a continuously closed box with its torsional stiffness. Check connector forces, local plate response, bolt access and any unequal loading of the pair.
Keep material sampling separate from member depth
A 20 mm flange in the largest listed 380 × 100 × 13 × 20 channel is in the 235 MPa yield band if that is the tensile-test location. The 380 mm depth is not material thickness, and the 13 mm web does not automatically set the flange specimen band. Sampling is governed by JIS G 0416 and the contractual test arrangement; the ordinary section table must also be distinguished from any applicable small-section route.
Use mass and fit as separate procurement checks
The 200 × 80 × 7.5 × 11 channel has area 31.33 cm² and 24.6 kg/m. A nominal 6 m piece therefore represents 147.6 kg on the reference basis. Neither that mass nor a matching depth proves compatibility with another channel family. Check clear web space, root radii, flange seating and bolt gauges before accepting a replacement, and agree the mass-settlement basis separately.
Material chemistry: heat analysis is not a universal alloy recipe
| Element | Heat-analysis requirement, mass % | Interpretation |
|---|---|---|
| C | No tabulated maximum | No grade-wide carbon cap may be inferred. |
| Si | No tabulated maximum | No SS400 silicon maximum is supplied by the material table. |
| Mn | No tabulated maximum | Do not import another grade’s manganese range. |
| P | 0.050 maximum | Heat-analysis limit, not a typical value. |
| S | 0.050 maximum | Heat-analysis limit, not a typical value. |
An absent limit does not mean zero content or a guaranteed “low-carbon” composition. Elements shown as dashes and unlisted alloying elements may be added as necessary; applicable additions are to be reported. Actual heat results are the input for welding or coating assessment. SS400 has no tabulated carbon-equivalent ceiling, so a Q235B, S235JR or SS540 chemistry/CEV table must not be copied onto this grade.
Keep a heat/ladle analysis distinct from an analysis of a sample cut from the finished section. The figures above are heat-analysis requirements; they are not a separately tabulated finished-product deviation schedule. The compiled material data do not provide numerical product-analysis deviations. If a supplementary product analysis is required, agree the sampling, test method and permitted-deviation/acceptance basis explicitly. Do not borrow GB/T 222 or invent a blanket percentage allowance for a JIS order.
Yield, elongation, bending and toughness
| t, mm | Minimum yield/proof stress, MPa | Tensile strength, MPa |
|---|---|---|
| t ≤16 | 245 | 400–510 |
| 16 <t ≤40 | 235 | 400–510 |
One N/mm² equals one MPa. Unless specified otherwise, yield is the upper yield point ReH; where no yield point appears, the 0.2% proof stress Rp0.2 is determined. The material’s thickness band is not selected by the overall depth or leg width. Sampling and specimen preparation follow JIS G 0416 and the order. The ordinary-section table below is also subject to the small-section provisions; the grade name alone does not select an elongation value.
| t, mm | Tensile test piece | Minimum elongation, % |
|---|---|---|
| t ≤5 | No. 5 | 21 |
| 5 <t ≤16 | No. 1A | 17 |
| 16 <t ≤40 | No. 1A | 21 |
The channel series reaches 20 mm nominal flange thickness. The 16 mm boundary can therefore matter on a flange-sampling reference, even where the web is thinner.
Small-section qualification: JIS G 3101 requires Annex JA for sections with leg length below 40 mm and permits that route within its 40 to under 70 mm section-leg scope. The applicable section dimension, mechanical route and specimen must be identified on the order/certificate; do not assume every small section uses the ordinary Table 3 elongation rows. Use the Annex JA specimen requirements for the ordered edition; the ordinary Table 3 elongation values above must not be used as a substitute.
| Item | Requirement or limitation |
|---|---|
| Bendability | 180° bend; inside radius 1.5t; No. 1 test piece (No. 3 may be used at thickness≤5 mm). |
| Actual bend test | May be omitted unless required by the purchaser; material still has to meet bendability. |
| Charpy impact | No mandatory SS400 temperature or absorbed-energy value in JIS G 3101. |
| Welding assessment | No automatic CEV limit or no-preheat guarantee; use actual heat chemistry and an appropriate procedure. |
A missing mandatory Charpy requirement is not a statement that the steel has no toughness; it means the grade alone does not qualify a specified impact performance. If low-temperature or other demonstrated toughness is needed, write the test regime into the order or select an approved material quality that specifies it. Any dual certification must satisfy every requirement of both named specifications, not merely a similar tensile range.
JIS G 3192:2024 reference dimensions and theoretical mass
All section dimensions and radii below are millimetres. Area is cm² and theoretical mass is kg/m. The numerical basis is JIS G 3192:2024; do not relabel older catalogue geometry as the current table. Published representative sizes do not establish size/grade availability, rolling frequency or stock. Any other section dimensions require the applicable agreement; no additional sizes have been invented here.
H is depth, B flange width, t1 web thickness and t2 the reference thickness on the tapered flange. r1 is the root radius and r2 the toe radius. The t2 gauge is measured across the clear outstand, as shown in the original diagram; it is not the thinner toe. Use the table for identification and the contractual standard for tolerances and inspection.
| Designation (H × B × t1 × t2) | H (mm) | B (mm) | t1 (mm) | t2 (mm) | r1 (mm) | r2 (mm) | A (cm²) | Mass (kg/m) |
|---|---|---|---|---|---|---|---|---|
| 75 × 40 × 5 × 7 | 75 | 40 | 5 | 7 | 8 | 4 | 8.818 | 6.92 |
| 100 × 50 × 5 × 7.5 | 100 | 50 | 5 | 7.5 | 8 | 4 | 11.92 | 9.36 |
| 125 × 65 × 6 × 8 | 125 | 65 | 6 | 8 | 8 | 4 | 17.11 | 13.4 |
| 150 × 75 × 6.5 × 10 | 150 | 75 | 6.5 | 10 | 10 | 5 | 23.71 | 18.6 |
| 150 × 75 × 9 × 12.5 | 150 | 75 | 9 | 12.5 | 15 | 7.5 | 30.59 | 24.0 |
| 180 × 75 × 7 × 10.5 | 180 | 75 | 7 | 10.5 | 11 | 5.5 | 27.20 | 21.4 |
| 200 × 80 × 7.5 × 11 | 200 | 80 | 7.5 | 11 | 12 | 6 | 31.33 | 24.6 |
| 200 × 90 × 8 × 13.5 | 200 | 90 | 8 | 13.5 | 14 | 7 | 38.65 | 30.3 |
| 250 × 90 × 9 × 13 | 250 | 90 | 9 | 13 | 14 | 7 | 44.07 | 34.6 |
| 250 × 90 × 11 × 14.5 | 250 | 90 | 11 | 14.5 | 17 | 8.5 | 51.17 | 40.2 |
| 300 × 90 × 9 × 13 | 300 | 90 | 9 | 13 | 14 | 7 | 48.57 | 38.1 |
| 300 × 90 × 10 × 15.5 | 300 | 90 | 10 | 15.5 | 19 | 9.5 | 55.74 | 43.8 |
| 300 × 90 × 12 × 16 | 300 | 90 | 12 | 16 | 19 | 9.5 | 61.90 | 48.6 |
| 380 × 100 × 10.5 × 16 | 380 | 100 | 10.5 | 16 | 18 | 9 | 69.39 | 54.5 |
| 380 × 100 × 13 × 16.5 | 380 | 100 | 13 | 16.5 | 18 | 9 | 78.96 | 62.0 |
| 380 × 100 × 13 × 20 | 380 | 100 | 13 | 20 | 24 | 12 | 85.71 | 67.3 |
Dimensional, shape and mass acceptance belongs to the ordered JIS G 3192 edition. Check depth/leg widths, thicknesses, straightness, twist and squareness or flange alignment as applicable, including the actual root/clearance where a connection depends on it. Agreement on theoretical versus actual-mass settlement is separate from the material tensile result. Catalogue rounding is not a dimensional tolerance.
Inspection documents, traceability and enquiry
The material standard’s 2024 inspection-document default, unless otherwise specified at order, is a JIS G 0415 inspection certificate 3.1. This describes the standard’s documentary requirement, not a claim that a particular independent inspection service or third-party approval is included. State any different or additional document requirement before quotation. The document must identify the actual rolled product, grade, heat/batch and applicable tests; an SS400 plate or bar certificate alone does not identify a supplied section.
- Specify the full section designation, SS400 material edition, dimensional edition, lengths and quantity. Mark special/non-general-purpose rows and any agreed departure from representative sizes.
- State the tensile specimen and applicable mechanical route where critical, including Annex JA for qualifying small sections. Actual bend or supplementary impact tests must be requested when required; do not infer test results from a grade suffix that does not exist.
- Keep heat analysis, any agreed finished-product analysis and dimensional inspection separately traceable. Include restricted chemistry, weld or coating requirements for review without assuming machining, coating, cutting or additional testing services are included.
- Confirm the commercial mass basis, delivery requirements and certificate traceability before release. The reference size tables are not a mill programme or an inventory listing.
Lead time: a typical new mill order is about 35 days. Stocked sizes:1–3 days, subject to enquiry and confirmation of the specific section, grade, quantity and delivery requirement. No table row is represented as immediately available stock.
Related products: comparison is not equivalence
The SS400 plate material page concerns a different product form; it does not replace the section’s sampling, shape or certificate identification. Its legacy catalogue text is not used as the numerical authority for the section tables above.
For a different standard system, see the S235JR UPE/PFC reference. A similar strength class is not an automatic replacement: material chemistry, toughness, sampling and the rolled shape must each meet the project specification.
The Q235B channels page is another material/shape comparison, not a dual-certification claim. Do not transfer GB dimensional or test-location rules to a JIS certificate.
The existing parallel-flange channel family overview remains a separate family guide. Its presence does not change the JIS section designation or authorize modification of an established hub.
Related SS400 section families: SS400 H-Beams, SS400 I-Beams, SS400 Angles. These pages describe distinct section geometries; the links do not state that the sections are interchangeable.
Frequently asked questions
Are JIS channels interchangeable with PFC or GB channels?
No. The JIS tapered channel has its own dimensions, radii, reference flange thickness and tolerances. A PFC has a different seating system; a GB or UPN channel also needs an independent shape comparison. Check the full designation and material acceptance, not only depth, before approving substitution.
What does 200 × 80 × 7.5 × 11 describe?
It identifies 200 mm depth,80 mm flange width,7.5 mm web and 11 mm reference flange thickness. The t2 gauge is at the midpoint of the clear outstand, not the toe. The illustrated JIS section has 12/6 mm root/toe radii,31.33 cm² area and 24.6 kg/m. Each of those details can matter for fit or settlement.
Why does the channel need a torsion check?
Its open cross-section has a shear centre that generally does not coincide with the centroid. A transverse force at an offset location can therefore introduce twist in addition to bending. Include the actual bracket or flange load line, restraint and end conditions in the model. A strong-axis bending stress calculation alone may not describe the installed member.
Can back-to-back channels be counted as a box?
Not by merely adding their masses or areas. Connector spacing, member separation, orientation and end load introduction must justify the assumed built-up action. A discontinuously connected pair is not automatically a continuously closed torsion box. Design the battens, spacers or stitch connections and check local load transfer and overall stability.
What is the JIS inner-flange angle?
The reference inner flange/web included angle is 95°, corresponding to a 5° incline from horizontal. This is not an unqualified 1:10 slope. The varying flange thickness and rounded root affect washer seating and bolt clearance. Use the ordered section geometry and a compatible connection detail rather than a generic flat-flange sketch.
Does the 13 mm web keep a 20 mm flange in the 245 MPa band?
Not for a specimen taken from that 20 mm flange. The relevant JIS rule is thickness at the actual test-piece location, not the thinnest wall in the section. At 20 mm, the ordinary section yield minimum is 235 MPa. The sampling arrangement must follow JIS G 0416 and the order; it is not inferred from overall channel depth or another country’s sampling convention.
Does an SS400 certificate guarantee weldability or impact results?
It does not supply a universal CEV cap or Charpy requirement. Check actual heat chemistry, delivery condition and a welding procedure appropriate to thickness, restraint and hydrogen control. If a project requires impact testing or tighter chemistry, those requirements need explicit agreement. A plate certificate sharing the grade name does not identify a channel by itself.
What makes a channel enquiry complete?
Include H × B × t1 × t2, JIS G 3101 SS400 and edition, JIS G 3192 edition, lengths, quantity, orientation where relevant, mass basis and document/test requirements. Identify paired-member or connection requirements without assuming fabrication is included. Typical mill delivery is about 35 days; stocked sizes are 1–3 days only subject to the individual enquiry being confirmed.
For an enquiry to Gangsteel, send a complete section and specification list. Size/grade feasibility, tests, documents and delivery are confirmed against that enquiry, not assumed from a nominal shape name.
