EN 10025-2 S355JR equal angle L 100 x 100 x 10 and unequal angle L 150 x 90 x 10 end views drawn to the same scale with principal axes
Original generated illustration — L 100 x 100 x 10 and L 150 x 90 x 10 at the same scale; schematic only, not a dimensioned drawing, stock photograph or material certificate.

S355JR Angles: Equal and Unequal Legs in One Grade

Gangsteel supplies EN 10025-2 S355JR equal and unequal angles for heavily loaded truss chords and diagonals, lattice towers, industrial bracing, crane-runway restraints and equipment frames where strength governs and the structure is enclosed or not exposed to low temperatures. Order as “L 150 × 150 × 15, EN 10025-2 S355JR”.

S355JR angle specification
ItemValueNote
MaterialEN 10025-2:2019 S355JR (1.0045)Impact quality 27 J at +20 °C
Section seriesEqual and unequal leg angles to EN 10056-1Hot-rolled, rounded root and toe; not for square-root angles
TolerancesEN 10056-2Leg length, thickness, out-of-square, straightness, mass
General deliveryEN 10025-1Testing, inspection documents, marking
SupplyGangsteel supplies EN 10025-2 S355JR equal and unequal anglesSizes, quantities and stock confirmed per enquiry
Former designationSt 52-3 was the closest DIN 17100 grade but required −20 °C impact; S355JR is not its direct equivalentCheck old drawings

Equal Angles in S355JR: Size Range

Equal-leg angle range in S355JR: thicknesses, mass, yield band and the thinnest leg that is not slender in compression
Leg size mmt mmkg/mReH MPaThinnest Class 3 tClass 4 thicknesses
L 25 × 253–41.12–1.453553 mm0
L 30 × 303–41.36–1.783554 mm1
L 35 × 354–52.09–2.573554 mm0
L 40 × 404–62.42–3.523555 mm1
L 45 × 453–72.09–4.63555 mm3
L 50 × 504–93.06–6.473556 mm2
L 55 × 554–63.38–4.953556 mm2
L 60 × 604–103.7–8.693557 mm3
L 63 × 635–6.54.82–6.17355none3
L 65 × 654–114.02–10.33557 mm3
L 70 × 705–105.37–10.33558 mm3
L 75 × 754–104.65–11.13559 mm5
L 80 × 805–106.17–11.93559 mm4
L 90 × 905–166.97–20.735510 mm5
L 100 × 1006–189.26–26.2355 / 34511 mm5
L 110 × 1106–1410.2–23.335512 mm6
L 120 × 1207–1612.9–28.335513 mm6
L 130 × 1308–1616–30.835514 mm6
L 140 × 1409–1819.3–37.2355 / 34515 mm6
L 150 × 15010–2023–44.2355 / 34517 mm7
L 160 × 16012–2029.3–47.3355 / 34517 mm5
L 180 × 18013–2235.7–58.6355 / 34519 mm6
L 200 × 20012–2836.8–82355 / 34522 mm10
L 250 × 25017–3564.4–12834527 mm10
L 300 × 30025–35112–15434532 mm7

The range covers 25 × 25 to 300 × 300 mm. Some sizes and thicknesses are specific to individual mills rather than listed in EN 10056-1, so name the full designation, for example L 100 × 100 × 10, and confirm the size at enquiry.

Equal Angle Properties in S355JR

Equal angles at the common t ≈ leg/10 proportion in S355JR: properties, yield band, gross squash load and class in compression
Designationkg/mA cm²c cmIy = Iz cm⁴iv cmWel cm³ReH MPaA·ReH kNClass, axial
L 25 × 25 × 31.121.420.7200.8000.4800.45035550Class 3
L 30 × 30 × 31.361.740.8401.400.5800.65035562Class 4
L 35 × 35 × 42.092.671.002.950.6801.1835595Class 3
L 40 × 40 × 42.423.081.124.470.7801.55355109Class 4
L 45 × 45 × 4.53.063.901.257.140.8702.20355138Class 4
L 50 × 50 × 53.774.801.4011.00.9703.05355170Class 4
L 55 × 55 × 64.956.311.5617.31.064.39355224Class 3
L 60 × 60 × 65.426.911.6922.81.175.29355245Class 4
L 63 × 63 × 6.56.177.851.7828.41.226.27355279Class 4
L 65 × 65 × 76.838.701.8533.41.267.18355309Class 3
L 70 × 70 × 77.389.401.9742.31.368.41355334Class 4
L 75 × 75 × 88.9911.42.1459.11.4611.0355405Class 4
L 80 × 80 × 89.6312.32.2672.21.5612.6355437Class 4
L 90 × 90 × 912.215.52.541161.7617.9355550Class 4
L 100 × 100 × 1015.019.22.821771.9524.6355682Class 4
L 110 × 110 × 1118.223.23.112592.1432.8355824Class 4
L 120 × 120 × 1221.627.53.403682.3542.7355976Class 4
L 130 × 130 × 1325.432.33.685062.5454.43551147Class 4
L 140 × 140 × 1429.437.53.966812.7367.93551331Class 4
L 150 × 150 × 1533.843.04.258982.9383.53551526Class 4
L 160 × 160 × 1638.449.04.531,1603.121013551740Class 4
L 180 × 180 × 1848.661.95.101,8703.521453452136Class 4
L 200 × 200 × 2059.976.35.682,8503.921993452632Class 4
L 250 × 250 × 2593.2119.07.116,9204.893873454106Class 4
L 300 × 300 × 30133170.08.5414,3005.866663455865Class 4

Unequal Angles in S355JR

Unequal angles 100 × 65 to 250 × 90 in S355JR: properties, yield band, gross squash load and class in compression
Designationkg/mA cm²cy cmcz cmIy cm⁴Iz cm⁴iv cmtan αReH MPaA·ReH kNClass, axial
L 100 × 65 × 78.7711.23.231.5111337.61.400.415355398Class 4
L 100 × 65 × 89.9412.73.271.5512742.21.400.413355451Class 4
L 100 × 65 × 911.114.13.321.5914146.71.390.412355501Class 3
L 100 × 65 × 1012.315.63.361.6315451.01.390.410355554Class 3
L 100 × 65 × 1113.417.03.401.6716755.11.380.408355604Class 3
L 100 × 65 × 1214.518.53.441.7118059.11.380.406355657Class 3
L 110 × 70 × 1013.417.13.691.7220765.11.500.396355607Class 3
L 110 × 70 × 1215.920.33.771.7924275.51.490.392355721Class 3
L 120 × 80 × 812.215.53.831.8722680.81.740.437355550Class 4
L 120 × 80 × 1015.019.13.921.9527698.11.720.435355678Class 4
L 120 × 80 × 1217.822.74.002.033231141.710.431355806Class 3
L 130 × 90 × 1016.621.24.162.193601421.940.469355753Class 4
L 130 × 90 × 1219.725.14.242.264201641.930.467355891Class 3
L 130 × 90 × 1422.829.04.332.344811881.930.4633551030Class 3
L 140 × 90 × 814.017.94.492.033601181.960.411355635Class 4
L 140 × 90 × 1017.422.14.582.114411441.950.409355785Class 4
L 140 × 90 × 1220.626.34.662.195181681.940.406355934Class 4
L 140 × 90 × 1423.830.44.742.275921911.930.4033551079Class 3
L 150 × 90 × 1018.223.25.002.045331461.950.360355824Class 4
L 150 × 90 × 1119.925.35.042.085811591.940.359355898Class 4
L 150 × 90 × 1221.627.55.082.126271711.940.358355976Class 4
L 150 × 100 × 1019.024.24.812.345531992.170.438355859Class 4
L 150 × 100 × 1222.528.74.892.426512332.160.4363551019Class 4
L 150 × 100 × 1426.133.24.982.507442652.150.4343551179Class 3
L 200 × 100 × 1023.029.26.932.011,2202102.150.2633551037Class 4
L 200 × 100 × 1227.334.87.032.101,4402472.140.2623551235Class 4
L 200 × 100 × 1431.640.37.122.181,6502822.120.2613551431Class 4
L 200 × 100 × 1533.843.07.162.221,7602992.120.2603551526Class 4
L 200 × 100 × 1635.945.77.202.261,8603162.110.2583551622Class 4
L 250 × 90 × 1231.239.79.501.642,5601871.810.1523551409Class 4
L 250 × 90 × 1436.146.09.601.722,9502141.800.1513551633Class 4
L 250 × 90 × 1640.952.19.701.813,3302391.790.1493551850Class 4

Legs up to 16 mm are rated at 355 MPa and legs from 16 to 40 mm at 345 MPa. The higher strength makes local buckling more critical: at ε = 0.81 the limit (b + h)/(2t) ≤ 11.5ε is about 9.3, so the common leg/10 proportion (L 50 × 50 × 5, L 100 × 100 × 10, L 150 × 150 × 15) is Class 4 in S355JR. L 100 × 100 needs t ≥ 11 mm and L 150 × 150 needs t ≥ 17 mm to be Class 3. Overall 109 of 192 equal thicknesses and 21 of 32 unequal angles are Class 4, so effective-area calculations are routine for this grade.

A·ReH is the gross characteristic squash load (gross area × yield). It is not a design resistance: it ignores partial factors, flexural and flexural-torsional buckling, the eccentricity of end connections, net-section effects at bolt holes and, for Class 4 sections, the reduced effective area. The class uses the EN 1993-1-1 rule for angles in compression: Class 3 when h/t ≤ 15ε and (b + h)/(2t) ≤ 11.5ε, otherwise Class 4, with ε = √(235/ReH). Angles do not reach Class 1 or 2 under this rule. Confirm with the design code and national annex used on the project.

S355JR Chemistry for Angle Sections

S355JR heat analysis, maximum mass %
Elementt ≤ 30 mm30 mm < t ≤ 40 mm (L 250 and L 300, t 31–35)
C0.240.24
Mn1.601.60
Si0.550.55
P / S0.040 / 0.0400.040 / 0.040
N0.012 (waived with total Al ≥ 0.020% or reported N-binding elements)0.012
Cu0.550.55
CEV0.450.47

Carbon may be up to 0.24% and CEV 0.45% for legs up to 30 mm. For the heavy L 250 × 250 and L 300 × 300 at 31–35 mm sizes the CEV ceiling rises to 0.47%, which matters for preheat in welded connections. Silicon is capped at 0.55%.

S355JR Tensile and Impact Requirements

S355JR properties for angles
Propertyt ≤ 16 mm16 mm < t ≤ 40 mm
Minimum ReH355 MPa345 MPa
Rm (3 ≤ t ≤ 100 mm)470–630 MPa470–630 MPa
Minimum A (L0 = 5.65√S0)22%22%
Charpy V, minimum27 J at +20 °C27 J at +20 °C
Angles in this bandAll unequal sizes; equal sizes up to t = 16Equal angles L 100 × 100 × 18 and L 150 to L 300 above 16 mm

The 27 J impact test is at +20 °C. For exposed towers and outdoor frames in cold climates, S355J0 or S355J2 is usually specified instead.

Designing with S355JR Angles

Higher yield pays off most in tension members and in stocky compression members. Gross squash load rises to about 682 kN for L 100 × 100 × 10, but because that angle is Class 4 in this grade, its compression resistance uses an effective area smaller than 19.2 cm². For slender single angles, buckling about v-v (iv = 1.95 cm for L 100 × 100 × 10) limits the benefit further. Thicker legs, double angles and star-battened pairs make better use of S355JR in compression.

Lattice tower legs, which are typically equal angles with diagonals bolted to both legs, are often designed to specific tower codes; check that the code accepts EN 10025-2 S355JR and its impact quality for the site climate.

S355JR Compared with Other Angle Grades

S355JR angles against other grades
GradeL 100 × 100 × 10 classUnequal angles Class 4 (of 32)CEV above 30 mm
S235JRClass 3100.35
S275JRClass 3140.40
S355JRClass 4210.47
S355J2Class 4210.47

Fabrication: Bolting, Welding and Galvanizing

Weld S355JR angles to a qualified procedure with matching consumables. Preheat depends on CEV, combined thickness and hydrogen level; heavy L 250 and L 300 angles above 30 mm need the most attention. Punching holes in thicker S355 legs may be restricted by the execution class; drilling or punch-and-ream avoids edge cracking. Galvanizing high-strength angles with punched holes and cold work warrants care to avoid liquid-metal-assisted cracking.

Delivery Condition, Inspection and Lead Time

What to state on an S355JR angle order
ItemSpecifyReason
DesignationL h × b × t, e.g. L 150 × 90 × 10Leg lengths alone do not fix thickness or mass
Delivery condition+AR or +N where requiredNot implied by the grade name
Impact testWhether the 27 J at +20 °C result must be reported, and specimen size for thin legsAngle legs run from 3 to 35 mm
Inspection documentEN 10204 3.1 for heat-specific resultsTraceability to the delivered pieces
DimensionsEN 10056-2 tolerances, lengths, cut listNominal values are not tolerances
Mass basisTheoretical or weighedAvoids invoicing disputes

Lead time: typical delivery is about 35 days for mill orders, and sizes available from stock can ship in 1–3 days. Stock is confirmed size by size at enquiry; the angle tables on this page are reference geometry, not a stock list.

RFQ Checklist

  • Full angle designation, quantity and lengths; equal and unequal sizes listed separately.
  • EN 10025-2 S355JR, delivery condition and any chemistry options such as the galvanizing silicon range.
  • Impact verification and EN 10204 document type.
  • Processing: cutting, punching or drilling of legs, notching, galvanizing.
  • Packing, marking and destination; whether stock sizes for 1–3 day dispatch are preferred over a mill order.

Other sections in the same grade: EN 10025-2 S355JR HEA and HEB beams, EN 10025-2 S355JR IPE beams and EN 10025-2 S355JR UPE and PFC channels. The hot-rolled steel angle range overview covers angles across grades, gussets and cleat plates are covered by EN 10025-2 S355JR steel plate, and the structural steel sections guide compares all section families.

The same equal and unequal angles in other EN 10025-2 grades: S235JR angles, S275JR angles, S355J2 angles.

Frequently Asked Questions

Which S355JR angles are Class 4 in compression?

Most thin-leg sizes. The common leg/10 proportion is already Class 4 because (b + h)/(2t) = 10 exceeds 11.5ε (about 9.3). 109 of 192 equal thicknesses and 21 of 32 unequal angles in the tables are Class 4.

How thick must an S355JR equal angle be to avoid Class 4?

Roughly t ≥ h/9.3 for legs up to 16 mm: L 100 × 100 needs 11 mm, L 150 × 150 needs 17 mm (at 345 MPa), and L 200 × 200 needs 22 mm.

Does CEV change for thick S355JR angles?

Yes. CEV is limited to 0.45% for t ≤ 30 mm and 0.47% for 30 < t ≤ 40 mm, which affects L 250 × 250 and L 300 × 300 at 31–35 mm.

Is S355JR the same as St 52-3?

No. St 52-3 required impact toughness at −20 °C, closer to S355J2. S355JR is tested at +20 °C.

Are S355JR angles suitable for transmission or telecom towers?

They are used in towers designed for enclosed or mild conditions, but tower codes and cold sites often require J0 or J2 impact quality. Check the project specification.

Does punching affect S355JR angle legs?

Punching cold-works the hole edge. Execution standards may limit full-size punching by thickness and execution class, or require reaming; galvanized members are particularly sensitive.

Why is the gross squash load not the resistance of a Class 4 angle?

For Class 4 sections only the effective area resists compression, and buckling about the weak axis reduces the resistance further. A·ReH is given only as a comparison value.

What lead time applies to S355JR angles?

About 35 days for mill orders and 1–3 days for stock sizes, confirmed per size at enquiry.

Other Products